Cw Id/Cw Message; Cw Id; Tx Interval Time - Kenwood TKR-750-850 Function Reference

Vhf fm repeater
Table of Contents

Advertisement

22 CW ID/CW MESSAGE

CW stands for Continuous Wave and it is one of the
telegraph methods (communication with Morse codes).
With this communication, the characters and numbers are
sent with the combination of dots and dashes. It has an
advantage to be able to keep wide area communication
with small transmit power.
It is possible to transmit a message using Morse code by
the CW ID function and the CW Message function.
The specification of the CW is compliant with the items in
the "FCC 90.425 Station identification" and "International
Morse Code".

22.1 CW ID

CW ID is a function to send a Morse code configured at
transmission by configuring Morse codes to each
channel. Each message has capability with a maximum of
32 characters and symbols. Also it can send a CW ID by
interlocking with a PF keys and an AUX I/O port. (Refer to
FPRG 13 Function List.)
You can configure the following functions relating to the
transmission of CW ID by KPG-91D.
CW ID

TX Interval Time

TX Delay Time
CW Speed
CW Mod. Delay Time
Audio Frequency
TX Required in Interval
CW ID Override
Send CW ID to RA
CW ID on Channel change
Encode with QT/DQT
Note:
# You cannot send the CW ID while scanning or pausing the Scan.
# When the CW ID On or the CW Message On function is enabled
while sending the CW ID, TKR-750/850/751/851 stops sending
the current CW ID and sends the newly configured CW ID.
53
22.1.1 CW ID
It is possible to compose a message with a maximum of
32 characters.
Table 22-1 Available Characters/Symbols
Characters and
Symbols
A,B...Y,Z
(
)
+
""
?
-
Space
0 - 9
=
/
.
,
'
:
! Configuration of KPG-91D
" Configuring the CW ID (Refer to FPRG 6.3.1 CW
ID.)
22.1.2 TX Interval Time
TX Interval Time is a duration to send each CW ID. You
can repeatedly send the CW ID with the interval
configured in this function.
Note: The TX Interval Time starts counting down when resetting
TKR-750/850/751/851, changing the channel, and activating
the CW ID On Function or the Scan Off Function.
! Configuration of KPG-91D
" Configuring the TX Interval Time (Refer to FPRG
6.3.2 TX Interval Time.)
Function Reference (FUNC)
Description
Alphabet (Large characters)
Left parenthesis
Right parenthesis
Adding symbol
Quotation mark
Question mark
Continuous line, subtracting symbol,
horizontal line
Space (You cannot enter the space
continuously or use it as the first letter of
the ID.)
Numbers
Double line
Slash
Period
Comma
Abbreviation mark
Colon
Version: 1.01 USA