Kenwood TKR-750-850 Function Reference page 55

Vhf fm repeater
Table of Contents

Advertisement

Function Name
Monitor On
Monitor On/Off
Multi-table Sub
Multi-table Main
Multi-table
Main/Sub
QT/DQT Decode Disable
QT/DQT Decode Enable
QT/DQT Decode Disable/Enable
QT/DQT Encode Disable
QT/DQT Encode Enable
QT/DQT Encode Disable/Enable
Repeat Disable
Repeat Enable
Repeat Disable/Enable
Reset
Scan Off
Version: 1.01 USA
The Signalling Decode function is disabled when the signal is applied to the PF [Monitor On] input
port. When a signal is detected with the Down Edge, you cannot switch the monitor Off after this
function is once enabled. It should be used with Monitor Off function.
The Signalling Decode function is switched disable and enable when the signal is applied to the
PF [Monitor On/Off] input port. You can use this function only when the signal is detected with the
Down Edge.
(Refer to 20.2.1 Trigger Detection for Auxiliary Input Ports.)
TKR-750/850/751/851 switches the signalling specified with the Multi-table Select to the Sub-
table signalling when a signal is applied to the PF [Multi-table Sub] input port.
I/O Function.)
When the signal is detected with the Down Edge, you cannot return to the Main-table after the
Sub-table is once selected. So it should be used with Multi-Table Main function.
TKR-750/850/751/851 switches the signalling specified with the Multi-table Select to the Main-
table when a signal is applied to the PF [Multi-table Main] input port.
Function.)
When the signal is detected with the Down Edge, you cannot switch to the Sub-table after the
Main-table is once selected. So it should be used with Multi-Table Sub function.
TKR-750/850/751/851 switches Main/Sub for the signalling specified with the Multi-table Select
when a signal is applied to the PF [Multi-table Main/Sub] input port.
Function.)
You can use this function only when the signal is detected with the Down Edge.
Trigger Detection for Auxiliary Input Ports.)
The QT/DQT Decode function is disabled when the signal is applied to the PF [QT/DQT Decode
Disable] input port. When a signal is detected with the Down Edge, you cannot switch the QT/
DQT Decode function On after this function is once enabled. So it should be used with enable
function.
This function is available even when TKR-750/850/751/851 is performing the repeat operation.
The QT/DQT Decode function is enabled when a signal is applied to the PF [QT/DQT Decode
Enable] input port. So it should be used with Disable function.
When the signal is detected with the Down Edge, you cannot switch the QT/DQT Decode function
Off after this function is once enabled.
The QT/DQT Decode function is switched disable and enable when a signal is applied to the PF
[QT/DQT Encode Disable/Enable] input port. You can use this function only when the signal is
detected with the Down Edge.
The QT/DQT Encode function is disabled when a signal is applied to the PF [QT/DQT Encode
Disable] input port. When the signal is detected with the Down Edge, you cannot switch the QT/
DQT Encode On after this function is once enabled. So it should be used with Enable function.
The QT/DQT Encode function is enabled when a signal is applied to the PF [QT/DQT Encode
Enable] input port. When the signal is detected with the Down Edge, you cannot switch the QT/
DQT Encode Off after this function is once enabled. So it should be used with Disable function.
The QT/DQT Encode function is switched disable and enable when a signal is applied to the PF
[QT/DQT Encode Disable/Enable] input port. You can use this function only when the signal is
detected with the Down Edge.
The Repeat operation is disabled when a signal is applied to the PF [Repeat Disable] input port.
You cannot configure this function if no channel is configured to the repeat operation.
When the signal is detected with the Down Edge, you cannot enable the Repeat operation after
this function is once enabled. It should be used with Enable function.
The Repeat operation is enabled when a signal is applied to the PF [Repeat Enable] input port.
You cannot configure this function if no channel is configured to the repeat operation.
When the signal is detected with the Down Edge, you cannot disable the repeat operation after
this function is once enabled. It should be used with Disable function.
The repeat operation is switched enable and disable when a signal is applied to the PF [Repeat
Disable/Enable] input port.
You cannot configure this function if no channel is configured to the repeat operation. You can use
this function only when the signal is detected with the Down Edge.
Detection for Auxiliary Input Ports.)
The TKR-750/850/751/851 resets the operations and returns to the default value when a signal is
applied to the PF [Reset] input port.
The Scan is disabled when a signal is applied to the PF [Scan Off] input port.
When a signal is detected with the Down Edge, you cannot enable the Scan after this function is
once enabled. So it should be used with On function.
Function Reference (FUNC)
Description
(Refer to 20.2.1 Trigger Detection for Auxiliary Input Ports.)
(Refer to 20.2.1 Trigger Detection for Auxiliary Input Ports.)
20 FUNCTION PORT
(Refer to 20.1 AUX
(Refer to 20.1 AUX I/O
(Refer to 20.1 AUX I/O
(Refer to 20.2.1
(Refer to 20.2.1 Trigger
48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tkr-751-85Tkr-750Tkr-850Tkr-751Tkr-851

Table of Contents