Kubota SM-E3B Series Workshop Manual page 86

Sm-e3b series
Table of Contents

Advertisement

SM-E3B SERIES WSM
Continuity across Regulator's Terminals
1. Measure with a circuit tester according to the list below.
NOTE
• For this test, use only Analog Meter and do not use a high
voltage tester such as a MΩ meter.
• This check sheet shows the results of the test conducted by
using the "Sanwa-made tester SP-10 and SP-15D" (Analog
Meter).
• Use of other testers than those above may show different
measured results.
measuring range.
• The judgement should be as below table.
"ON" if the indicator moves, otherwise "OFF".
Check Table (
: ON,
Tester +
Terminal
Tester −
Blue
Terminal
Blue
Black
Blue
Code
colors
Green
Yellow
Red
(1) Blue
(2) Black
(3) Blue
Regulating Voltage
1. Complete the charging circuit with a fully charged battery and
operate the dynamo at the specified speed.
2. Measure the output voltage with a volt meter.
3. If the measurement is not within the specified values, replace the
dynamo.
Regulating output
Factory spec.
voltage
S-25
DIESEL ENGINE
Ω shall be used as the unit for the
: OFF)
Code colors
Black
Blue
Green
(4) Green
(5) Yellow
(6) Red
14 to 15 V at
5200 min
KiSC issued 03, 2011 A
Yellow
Red
W1021509
-1
(rpm)
W1022299