Setting Sensor Alarms - HIKVISION DS-7604NI-VP User Manual

Ds-7600ni series
Hide thumbs Also See for DS-7604NI-VP:
Table of Contents

Advertisement

User Manual of DS-7600NI Series NVR

8.2 Setting Sensor Alarms

Purpose:
Set handling method of an external sensor alarm.
Steps:
1. Enter Alarm Settings of System Configuration and select an alarm input.
Menu> Configuration> Alarm
Select Alarm Input tab to enter Alarm Input Settings interface.
Figure 8. 4 Alarm Status Interface of System Configuration
2. Set up the handling method of the selected alarm input.
Check the Setting checkbox and click Handling button to set up its alarm response actions.
3. Select Trigger Channel tab and select one or more channels which will start to record or become full-screen
monitoring when an external alarm is input.
4. Select Arming Schedule tab to set the channel's arming schedule.
Choose one day of a week and Max. eight time periods can be set within each day.
Note:
Time periods shall not be repeated or overlapped.
5. Select Handling tab to set up alarm response actions of the alarm input (please refer to Chapter Setting
Alarm Response Actions).
Figure 8. 5 Alarm Input Setup Interface
110

Advertisement

Table of Contents
loading

Table of Contents