Gas Valve - GE Profile DPVH890EJ Technical Service Manual

Dryer with steam
Table of Contents

Advertisement

To remove the half-power coil:
1.
Remove the drum. (See
2.
Disconnect the 2 wires from the half-power coil.
3.
Note the position of the locator pin inserted in
the coil bracket.
4.
Remove the Phillips-head screw and the coil
bracket that holds the coil to the valve body.
Note: Upon reassembly, ensure the locator pin is
inserted into the hole provided in the coil bracket.

Gas Valve

The burner assembly utilizes a 2-stage gas valve
that ensures better heat control:
First stage – low fl ame – low heat
Second stage – normal fl ame – high heat
Control board regulates valve operation for
proper heat levels
The gas valve is attached to a bracket located in the
bottom, right, front corner of the dryer cabinet.
To remove the gas valve:
1.
Shut off the gas supply to the unit.
2.
Disconnect gas supply from the burner inlet pipe.
3.
Remove the drum. (See
4.
Remove 3 screws and the vapor shield.
Vapor Shield
.)
Drum
Locator Pin
.)
Drum
5.
Disconnect the coil wire harness from each coil
and the 2 wires from the half-power coil.
6.
Disconnect the ignitor wire harness and the 2
wires from the fl ame detector.
7.
Remove the 2 Phillips-head screws that attach
the gas valve bracket to the dryer fl oor.
8.
Pull the bracket toward the front of the dryer to
disengage tabs from dryer fl oor.
Gas
Valve
Bracket
9. Remove the coils from the gas valve. (See
.)
Valve Coils
10. Turn the bracket over. Remove the 3 Phillips-
head screws that attach the gas valve to the
gas valve bracket.
Caution: The ignitor is very fragile. To prevent
breaking the ignitor, care must be taken when
installing the gas valve.
Note: Upon reassembly, ensure the gas valve
is inserted under the 2 tabs located in
bracket
the dryer fl oor.
– 26 –
Disconnect
Tab
Disconnect
Disconnect
Disconnect
Disconnect
Gas

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profile dpvh890gj

Table of Contents