Error Codes - GE Profile DPVH890EJ Technical Service Manual

Dryer with steam
Table of Contents

Advertisement

Error Codes

Error
Component,
Code
System, or Test
E1
Interface EEPROM
E101
Power EEPROM
E2
Inlet Short
E4
Inlet Open
E3
Outlet Short
E5
Outlet Open
E61
Check Electrical
Connection
E81
Power Model
E10
Blower Motor
E11
Blocked Airfl ow
E12
Drum Motor
E16
LIN Comm Fail
E17
VFD Communication
Error
E18
Stuck Button
Description and Corrective Action
Reading or writing improperly. Replace UI board.
Reading or writing improperly. Replace power board.
Inlet thermistor shorted; check and replace if necessary.
Inlet thermistor open; check and replace if necessary.
Outlet thermistor shorted; check and replace if necessary.
Outlet thermistor open; check and replace if necessary.
Input voltage too high; please check power connections.
No model select connector detected; check model selector on power
board.
Blower motor is not rotating properly. Please check.
Check ventilation system.
Motor is not rotating properly or centrifugal switch is bad. Please check.
There is a problem with the communication between the machine
control and the UI control.
There is a problem with the serial communication interface between
the UI and the VFD.
Stuck keys. Please check.
– 43 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profile dpvh890gj

Table of Contents