GE Profile DPVH890GJ Dimensions And Installation Information
GE Profile DPVH890GJ Dimensions And Installation Information

GE Profile DPVH890GJ Dimensions And Installation Information

7.5 cu. ft. colossal capacity gas dryer with steam
Hide thumbs Also See for Profile DPVH890GJ:

Advertisement

DPVH890GJ
7.5 Cu. Ft. Colossal Capacity Gas Dryer With Steam
GE Profile
Dimensions and Installation Information (in inches)
Gas Dryer Rating
120V
60Hz, 6A
Exhaust Options: 3-way via rear, right, and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 30-amp circuit breaker or
a time-delay fuse, is required.
LP Conversion Kit: WE25M46
Note: Dryer wall outlet must be located within 36"
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
or
service,
27"
32.34"
32.34
39-3/4"
DPVH880
Specification Revised 5/09
39-3/4"
4-1/8"
3"
270199

Advertisement

loading
Need help?

Need help?

Do you have a question about the Profile DPVH890GJ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GE Profile DPVH890GJ

  • Page 1 Installation Information: For complete information, see installation instructions packed with your dryer. For answers to your Monogram, GE Profile ® ™ ® appliance questions, visit our website at ge.com or call GE Answer Center service, ® 800.626.2000. 27” 39-3/4” 32.34” DPVH880 32.34...
  • Page 2 0" either side, 3" front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52". • C loset doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • N o other fuel-burning appliance shall be installed in the same closet with a gas dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors.
  • Page 3 (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. For more information on venting kits and accessories, please call 1-800-GE-CARES. Best performance Maximum length of 4" dia. rigid metal duct Exhaust hood type Number 90°...
  • Page 4 • Baffle Dry - Built-in drying rack and hanger-clip design multiplies the drying options for hard-to-dry items or delicates • CleanSpeak Communication System - The washer communicates ™ electronically with the dryer, which then presets dry cycles for better clothes care, increased time savings and greater convenience • Stainless Steel Drum - Resists rust and won't chip, peel or snag clothes • Delay Start - Lets you do the laundry on your terms • Optional Stacking Bracket (GEFLSTACK) - Available at an additional cost • Model DPVH890GJMG – Champagne • Model DPVH890GJMV – Vermillion Red...