Control Board Assembly; Power Board - GE Profile DPVH890EJ Technical Service Manual

Dryer with steam
Table of Contents

Advertisement

Power Board

The power board is mounted in a plastic housing
that is attached to a support bracket located
under the top panel. The power board is inverted
(component side facing down), and protected from
moisture damage with a vapor shield.
To remove the power board:
1.
Remove the control and top panels. (See
and
.)
Panel
Top Panel
2.
Separate the steam generator outlet hose at the
coupler.
3.
Remove the Phillips-head screw that attaches
the right side of the vapor shield to the cabinet.
4.
Lift and place the vapor shield over the left side
of the cabinet.
Note: In the following step, a board standoff is
installed under each power board screw. To prevent
a standoff from falling into the dryer, capture each
standoff when removing each power board screw.
5. Remove the 4 Phillips-head screws that attach
the power board to the support bracket.
6. Mark and disconnect the wire harnesses and the
ground wire from the power board assembly.
Model Selector Harness
Note: If replacing the power board, transfer the
model selector harness to the replacement power
board in the same location as on the original.
Control
Board Standoff (1 of 4)

Control Board Assembly

The control board assembly is mounted in a plastic
housing that is attached to the inside of the control
panel. It consists of 3 circuit boards connected by
ribbons. The boards and the plastic housing are
replaced as an assembly.
Operation of the control board assembly can be
checked by using the service test mode. (See
.)
Test Mode
Error codes that are specifi c to the control board
can initiate error codes E1 and E18. (See S
.)
Mode
To remove the control board assembly:
Caution: To avoid marring the control panel, place
the panel face down on a protective surface.
1.
Remove the control and top panels. (See
and
Panel
Top Panel
2.
Remove the 5 Phillips-head screws that attach
the control board plastic housing to the control
panel. Remove the housing.
3. Remove the 26 Phillips-head screws that attach
the control board assembly to the plastic
housing.
4. Remove the wire harness from connection J1.
– 33 –