Water Fill Timer

The water fi ll timer is mounted on the right side of
the support bracket.
To remove the water fi ll timer:
Caution: To avoid marring the control panel, place
the panel face down on a protective surface.
1.
Remove the control and top panels. (See
and
)
Panel
Top Panel.
2.
Separate the steam generator outlet hose at the
coupler.
3.
Remove the Phillips-head screw that attaches
the right side of the vapor shield to the cabinet.
4.
Lift and place the vapor shield over the left side
of the cabinet.
5.
Mark and disconnect the wiring from the timer.
6.
Remove the Phillips-head screw that attaches
the water fi ll timer to the support bracket.