Control Panel; Dryer Components - GE Profile DPVH890EJ Technical Service Manual

Dryer with steam
Table of Contents

Advertisement

WARNING: Sharp edges may be exposed when
servicing the dryer. Use caution to avoid injury.
Wear Kevlar gloves or equivalent protection.
Caution: After any service, repair, or installation
of a new component, ensure all vapor shields are
properly installed.
Note: Combined Phillips-head/square-drive recess
screws are utilized throughout this appliance. Either
Phillips or square-drive screwdrivers can be used to
extract or install these screws.

Control Panel

Removal of the control panel provides access to the
control board assembly. The control panel is held
in place with 1 screw behind the control knob and
4 key slots inside the control panel that engage 4
grommets (2 on each side) attached to the shield.
To remove the control panel:
Note: In the following step, the knob is held in place
by 4 plastic clips and may require some effort to
remove.
1.
Remove the rotary knob by pulling straight out.
2. Remove the Phillips-head screw located inside
the control knob recess.

Dryer Components

3. Raise the control panel vertically to disengage
the 4 key slots from the 4 grommets.
4. Remove the wire harness from the user
interface board.
Caution: To avoid marring the control panel, place
the panel face down on a protective surface.
– 12 –
Disconnect

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profile dpvh890gj