Vent Termination Diagram - Jøtul GF 370 DV Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

A maximum of two
90° or four 45° elbows
may be used. When-
ever possible, use 45°
elbows instead of 90°
elbows as they of-
fer less restriction to
the flow of flue gases
and intake air. Use of
elbows may adversely
affect IPI functional-
ity. In such cases, CPI
mode should be used.
Reduce the overall
horizontal run by
4 feet for each 90°
elbow, and 2 feet for
each 45° elbow.
When two or more
elbows are used in a
horizontal run, a less
restricted setting may
be more effective than
that indicated by the
termination zone dia-
gram.
35 Ft.
(10.67 m)
30 Ft.
(9.14 m)
25 Ft.
(7.62 m)
20 Ft.
(6.10 m)
15 Ft.
(4.57 m)
ZONE
B
10 Ft.
(3.05 m)
ZONE
6 ft. Min.
Vertical
A
Termination
5 Ft.
(1.52 m)
2 Ft.
(61cm)
Required
Min.
Vertical
Rise
Figure 17 . Vent Termination Diagram.
Intake Air - Fully Closed
Full Exhaust Restriction
ZONE
C
Intake Air - Half Closed
Half Exhaust Restriction
Intake Air - Fully Open
No Exhaust Restriction
ANY VENTING WITH A VERTICAL RISE MUST
TERMINATE (END) WITHIN THE SHADED AREAS.
5 Ft.
10 Ft.
(1.52 m)
(3.05 m)
H O R I Z O N TA L R U N
138914 Rev. K / 7.27.10
ZONE
D
R e q u i r e s
u s e o f C P I
M o d e .
S e e t e x t f o r
d e ta i l s .
20 Ft.
15 Ft.
(6.09 m)
(4.57 m)
13