Flame Height - Valor VENTANA 1200EAN Installation & Operating Instructions Manual

Direct vent zero clearance fireplace
Table of Contents

Advertisement

Operation Modes
STANDBY MODE—Ignited pilot only.
MAN MODE —Manual Mode. You can use this mode to adjust the flame height up or down.
man
TEMP MODE —Daytime Temperature Mode (appliance must be in Standby mode; pilot ignited): The room
temp
temperature is measured and compared to the set temperature. The flame height is then automatically adjusted to
achieve the Daytime set temperature.
TEMP MODE—Nighttime Setback Temperature Mode (appliance must be in Standby mode, pilot ignited): The room
temp
temperature is measured and compared to the Nighttime Setback temperature. The flame height is then automatically
adjusted to achieve the Nighttime Setback temperature.
TIMER MODE—(appliance must be in Standby mode, pilot ignited): The Timer setting allows you to set two burner
timer
ON times and two burner OFF times for every 24-hour period.
Changing the Mode of Operation
Briefly pressing the SET button changes the mode of operation in the following order:
man
temp
temp
NOTE: MAN mode can also be reached by pressing either the
Mode
Sun
TEMP
Daytime temperature setting
TIMER
Start time setting

Flame Height

The flame height can be adjusted in the following manners. In STANDBY mode,
1. Press the
(large flame) button to turn on the main burner.
2. Press the
(large flame) button to increase the flame height.
3. Press the
(small flame) button to decrease the flame height or to go to pilot Standby position.
For fine adjustments, tap the
NOTE: While pressing either button, a symbol indicating transmission appears on the upper right hand corner of the
display. The receiver confirms transmission with an acoustic signal.
Time
To set the time, follow the steps below.
1. The display indicates °C/24-hour or °F/12-hour clock. To change from one to the other, press
and hold both the OFF and
2. To set the time, hold down both the
3. Quickly press the
button to set the hour and the
Note: You must start setting the time while the display is flashing. If it stops flashing, go back to
2.
4. Press the OFF button to return to manual mode or simply wait and it will automatically return
to Manual mode.
Remote Control Operation
and back to
timer
Moon
Nighttime temperature setting
Stop time setting
and
buttons.
buttons until the display changes.
and
buttons until the display flashes. Let go.
.
man
or
buttons.
button to set the minutes.