Vent Material
This unit is approved for installation using
4 x 6-5/8 inches coaxial direct vent pipe and
accessories manufactured by Simpson Dura-Vent.
Follow the installation instructions supplied with the
individual venting accessories.
Simpson Dura-Vent DV Venting Accessories
Termination Caps
• 46DVA-HC—Standard Coaxial Horizontal
• 46DVA-VC—Standard Coaxial Vertical
• 46DVA-VCH—High Wind Coaxial Vertical
• 46DVA-VCE—Extended Coaxial Vertical
• 46DVA-SNK14—Snorkel, 14" Rise
• 46DVA-SNK36—Snorkel, 36" Rise
DV 45º Elbows
• 46DVA-E45—Galvanized
• 46DVA-E45B—Black
DV 90º Elbows
• 46DVA-E90—Galvanized
• 46DVA-E90B—Black
Pipes 4" x 6-5/8"
• 46DVA-06—Galvanized, 6" long
• 46DVA-06B—Black, 6" long
• 46DVA-09—Galvanized, 9" long
• 46DVA-09B—Black, 9" long
• 46DVA-12—Galvanized, 12" long
• 46DVA-12B—Black, 12" long
• 46DVA-18—Galvanized, 18" long
• 46DVA-18B—Black, 18" long
• 46DVA-24—Galvanized, 24" long
• 46DVA-24B—Black, 24" long
• 46DVA-36—Galvanized, 36" long
• 46DVA-36B—Black, 36" long
• 46DVA-48—Galvanized, 48" long
• 46DVA-48B—Black, 48" long
Flashing
• 46DVA-F6—Roof 0/12–6/12
• 46DVA-F12—Roof 7/12–12/12
• 46DVA-FF—Flat roof
Other accessories
• 46DVA-WT—Wall Thimble
• 46DVA-SC—Storm Collar
• 46DVA-DC —Decorative Plate
• 46DVA-CS—Cathedral Ceiling Support
• 46DVA-FS—Ceiling Firestop / Floor Support
• 46DVA-WS—Wall Strap
• 46DVA-VSS —Vinyl Siding Standoff
• 46DVA-ES —Elbow Strap
• 46DVA-WG—Terminal Guard
16

Venting

Wall Thickness
The appliance vent is suitable for penetrating a
combustible wall assembly up to 8 inches in thickness.
A non-combustible wall can be of any thickness up to
the maximum horizontal run of vent pipe allowed for the
particular installation.
Framing Vent in Combustible Walls &
Ceilings
When penetrating through combustible walls and
ceilings, frame a minimum of 10 x 10 inches opening
and ensure that the insulation is kept clear of the vent
pipe using either a wall thimble or an attic insulation
shield. Follow the installation instructions supplied with
the individual venting components.
Align the vent
center to the
center of the
frame
10" (254 mm)
10" (254 mm)