User-Specified Reread Delay

If you want to set your own length for the reread delay, scan the bar code below,
then set the delay (from 0-30,000 milliseconds) by scanning digits from the
inside back cover, then scanning Save .
User-Specified Reread Delay

Centering

Use Centering to narrow the scanner's field of view to make sure the scanner
reads only those bar codes intended by the user. For instance, if multiple codes
are placed closely together, centering will insure that only the desired codes are
read.
If a bar code is not touched by a predefined window, it will not be decoded or
output by the scanner. If centering is turned on by scanning Centering On, the
scanner only reads codes that pass through the centering window you specify
using the Left of Centering Window, or Right of Centering Window bar
codes.
In the example below, the red line is the full scanner field of view and the white
boxed area is the centering window. The centering window has been set to
20% left and 30% right, as shown in the legend at the bottom. Since Bar Code
1 passes through the centering window, it will be read. Bar Code 2 does not
pass through the centering window, so it will not be read.
Bar Code 1
Bar Code 2
0%
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
Scan Centering On, then scan one of the following bar codes to change the left
or right of the centering window. Then scan the percent you want to shift the
centering window using digits on the inside back cover of this manual. Scan
Save. Default Centering = 40% for Left, 60% for Right.