Output Sequence Example
In this example, you are scanning Code 93, Code 128, and Code 39 barcodes,
but you want the image scanner to output Code 39 1st, Code 128 2nd, and
Code 93 3rd, as shown below.
Note: Code 93 must be enabled to use this example.
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
SEQBLKsequence editor start command
62
code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all lengths
41
start character match for Code 39, 41h = "A"
FF
termination string for first code
6A
code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all lengths
42
start character match for Code 128, 42h = "B"
FF
termination string for second code
69
code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths
43
start character match for Code 93, 43h = "C"
FF
termination string for third code
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on page 3-12, but assume a <CR> suffix and
specific code lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF