SECTION 1—GENERAL GUIDELINES
SECTION 1—GENERAL GUIDELINES
WARNING
SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation
and use of this product.
Check all parts for shipping damage before using. In case of damage, DO NOT use the equipment. Contact 
the dealer for further instructions.
The Invacare patient lift is NOT a transport device. It is intended to transfer an individual from one resting 
surface to another (such as a bed to a wheelchair). Moving a person suspended in a sling over ANY distance 
is NOT recommended.
DO NOT attempt to transfer without the approval of the patient's physician, nurse or medical assistant. 
Thoroughly read the instructions in this Owner's Manual, observe a trained team of experts performing the 
lifting procedures and then perform the entire lift procedure several times with proper supervision and a 
capable individual acting as a patient.
Invacare Stand Assist and Transfer slings are specifically designed to be used in conjunction with Invacare 
patient lifts. Slings and accessories designed by other manufacturers are not to be utilized as a component 
of Invacare's patient lift system. Use the sling that is recommended by the individual's doctor, nurse or 
medical assistant for the comfort and safety of the individual that is being lifted.

Weight Limitation

DO NOT exceed the maximum weight limitation of the patient lift. The Get‐U‐Up lift has a weight limitation 
of 350 lbs.

Assembling the Lift

DO NOT overtighten the mounting hardware. This will damage the mounting brackets.

Using the Sling

Individuals that use the Stand Assist Sling MUST be able to support the majority of their own weight, 
otherwise injury may occur.
Stand Assist Slings: DO NOT use the stand assist sling in combination with the patient lift as a transport 
device. It is intended to transfer an individual from one resting surface to another (such as a bed to a 
wheelchair). Moving a person using the stand assist sling in combination with the patient lift over ANY 
distance is NOT recommended.
Stand Assist Slings: Individuals that use the stand assist sling MUST be able to support the majority of their 
own weight, otherwise injury can occur. Before lifting the patient, make sure the bottom edge of the stand 
support sling is positioned on the lower back of the patient and the patientʹs arms are outside the stand assist 
sling. The belt MUST be snug, but comfortable on the patient, otherwise the patient can slide out of the sling 
during transfer, possibly causing injury.
Transfer Slings: Before lifting the patient, make sure the bottom edge of the transfer sling is at the base of the 
spine and the patientʹs arms are outside the transport sling. 
Transfer Slings: DO NOT raise the patient to a full standing position while using the transfer sling, otherwise 
injury may occur.
DO NOT use any kind of material (such as a plastic back incontinence pad or seating cushion) between the 
patient and sling material that may cause the patient to slide out of the sling during transferring.
After each laundering (in accordance with instructions on the sling), inspect sling(s) for wear, tears, and 
loose stitching.
Bleached, torn, cut, frayed, or broken slings are unsafe and could result in injury. Discard IMMEDIATELY.