10
Stove Installation
Hearth Requirements
•
Must extend 16" in front of the insert (18" in Canada) and 8" on both sides (min. 26" deep by 40-1/4" wide)
•
Must be non-combustible and at least .018" thick (26 gauge)
Drafting Performance
This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure, topography,
or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.), may adversely affect
draft. Travis Industries can not be responsible for external forces leading to less than optimal performance.
Leveling Bolt Installation
Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install, raise
the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the insert. Adjust
the bolts until they extend the same height as the hearth steps up. After the insert is installed, fine-tune
the leveling bolts to level the insert.
This distance is the
hearth step-up. The
leveling bolts should
stick out this far from the
base of the insert.
Hearth
© Travis Industries
(for qualified installers only)
Fireplace
100-01233_000
The leveling bolts go
into the holes at the
rear corners of the
insert.
Figure 5
4090819