Page 1
MICROLIFE ® CARDIO+ Blood Pressure Monitor For accurate blood pressure measurement Instruction Manual...
Page 2
Your retailer or pharmacy can provide you with the contact information pressure. of the Microlife dealer in your country. Or visit www.microlife.com for more information about our products. The Microlife Cardio+ Blood Pressure Monitor is a reliable medical device designed for use with your iPhone, iPad, or iPod touch.
Creating, Selecting, or Deleting a User Profile ........11 Charging the Microlife Cardio+ Blood Pressure Monitor ....5 Appendix Downloading the Microlife Cardio+ App from the App Store ....5 Battery Power Indicators ..............11 Creating a User Profile ..............5 Error Messages................12 Setting a Blood Pressure Target ............
What is included: • Microlife Cardio+ Dock x 1 9) Measurement 10) Report • Preformed Cuff, Size M–L (22–42 cm) x 1 11) Settings • USB Cable for Charging Battery x 1 12) Users • Carrying Case x 1 • Instruction Manual x 1 •...
USB cable. Connect to a power outlet and charge the dock App Store for 2 hours. Go to the App Store and search for «Microlife Cardio+». Once this app • During the charging process, the « » button lights up in yellow.
2 cm (0.75 inches) above your elbow, with the tube on the inside of Taking Measurements with the your arm. Microlife Cardio+ 2 cm (0.75 inches) Before Taking a Measurement • Support your arm so that it is relaxed. Ensure that the cuff is at the same height as your heart.
Taking a Measurement measurement is also recommended by doctors in most of the medical guidelines for hypertension management. • Open the «Microlife Cardio+» app automatically by plugging the iOS device to the monitor dock. Alternatively, click on the app displayed During Measurement on the iOS device screen.
Completed Measurement Pulse Arrhythmia Detection (PAD) Indicator • After the results are shown, the measurement is complete. The « » symbol indicates that certain pulse irregularities were detected during the measurement: • Your systolic and diastolic blood pressure and your pulse are displayed in the results.
Page 10
Classification of Adult’s Blood Pressure Values in Accordance with the World Health Organization (WHO) in 2003. Range Systolic (mmHg) Diastolic (mmHg) Recommendation Consult your doctor Blood pressure too low 100–120 60–80 Self-check Blood pressure optimum 120–130 80–85 Self-check Blood pressure normal 130–140 85–90 Consult your doctor...
Managing the Measurement Data Saving Data taken in the same month. To view data taken in different months, swipe the screen horizontally. • Press «Save» to store the measurement results, including • Viewing Data in a Line Graph: Turn the iOS device horizontally. To measurement mode, date, and time.
Managing a User Profile Appendix Creating a User Profile Battery Power Indicators Creating a profile for an individual user ensures that each individual's The « » button on the blood pressure monitor may show the data is stored separately. Go to «User» and choose «+» to create a following: new user.
Repeat the measurement, keeping your arm still. Low battery The battery power in the Microlife Cardio+ Blood Pressure Monitor «ERR 3» No pressure in Adequate pressure cannot be Dock is too low. Charge the dock the cuff generated in the cuff.
Facts about Blood Pressure and Self- • Take at least two measurements per day - one in the morning and one in the evening. Measurement • It is quite normal for two measurements taken in quick succession to • Blood pressure is the pressure of the blood flowing in the arteries, produce significantly different results.
We recommend that this device is tested for accuracy every 2 years or • Never open the device. after any mechanical impact (e.g., being dropped). Contact Microlife’s • Use only the cuff provided. service center to arrange a test.
Page 17
Guidance and manufacturer's declaration - electromagnetic emissions The BP4GAPO-2M is intended for use in the electromagnetic environment specified below. The customer or the user of the BP4GAPO-2M should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance The BP4GAPO-2M uses RF energy only for its internal function.
Page 18
Guidance and manufacturer's declaration - electromagnetic immunity The BP4GAPO-2M is intended for use in the electromagnetic environment specified below. The customer or the user of the BP4GAPO-2M should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance Electromagnetic environment-guidance level...
Page 19
Guidance and manufacturer's declaration - electromagnetic immunity The BP4GAPO-2M is intended for use in the electromagnetic environment specified below. The customer or the user of the BP4GAPO-2M should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance Conducted RF 3 Vrms Not applicable...
Page 20
Recommended separation distance between portable and mobile RF communication equipment and the BP4GAPO-2M The BP4GAPO-2M is intended for use in a electromagnetic environment in which radiated RF disturbance are controlled. The customer or the user of the BP4GAPO-2M can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the BP4GAPO-2M as recommended below, according to the maximum output power of the communications equipment.
Page 23
Europe / Middle-East / Africa Asia North / Central / South America Microlife AG Microlife Corporation Microlife USA, Inc. Espenstrasse 139 9F, 431, RuiGang Road, NeiHu 1617 Gulf to Bay Blvd., 2nd Floor Ste A 9443 Widnau / Switzerland Taipei, 11492, Taiwan, R.O.C.