Technical Data - Stanley Errigal Solid Fuel 47K CookerBoiler & Non Boiler Operating Instructions Manual

Errigal solid fuel 47k cooker boiler & non boiler
Table of Contents

Advertisement

CHIMNEY DRAUGHT:
FLUE DIAMETER:
BOILER TAPPINGS:
TEST PRESSURE OF BOILER (Where applicable):
COOKER WEIGHT:
SPACE HEATING:
47K
Nominal Outputs - Manufactured smokeless fuels kW:
Typical refuelling intervals to obtain nominal
outputs
Nominal heat output to space 4.5kW
Flue gas mass flow
Flue gas temp at nominal output
Gross Weight 263 kgs
Flue outlet 127 mm
This appliance has been tested in accordance
with BS EN 13240
High output cannot be maintained unless fuel is being burned at the above rates. The output for wood will be
lower owing to the lower calorific value of the fuel.
Nominal Outputs - Wood Fuel kW:
Typical refuelling intervals to obtain nominal
outputs
Nominal heat output to space 5.7 kW
Flue gas mass flow
Flue gas temp at nominal output
Gross Weight 263 kgs
Flue outlet 127 mm
This appliance has been tested in accordance
with BS EN 13240
All technical data are taken under laboratory conditions and may vary in use, flue draught conditions will effect
performance

TECHNICAL DATA

15 pa.
5" (127mm)
1" BSP (28mm)
40 PSI (2.75 Bar)
263 Kgs (579 lbs)
5 kW's (17, 000) Btu's
2 hours
Nominal heat output to water 7.5 kW
9.0 g/s
o
293
C
Boiler Capacity 7.5 Litres
Flue draught 15 Pascals
1 hours
Nominal heat output to water 5.4 kW
10.4 g/s
o
279
C
Boiler Capacity 7.5 Litres
Flue draught 15 Pascals
5
4 kgs
4 kgs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Errigal solid fuel 47k cooker boiler & non boiler

Table of Contents