Specifications Of Electrical Parts - Toshiba RAS-M10UKV-E3 Service Manual

Split type
Table of Contents

Advertisement

5-1. Indoor Unit
RAS-M10UKV-E3, RAS-M13UKV-E3, RAS-M16UKV-E3
RAS-M10UKCV-E3, RAS-M13UKCV-E3, RAS-M16UKCV-E3
No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
DC-DC transformer (T01)
4
Microcomputer
Heat exchanger sensor
5
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C03)
9
Fuse (F01)
10
Power supply IC (IC01)
11
Varistor (R21, R109)
12
Resistor (R01)
13
Louver motor

5. SPECIFICATIONS OF ELECTRICAL PARTS

KMH450VNSN120M25C
Type
ICF-35-19-4
( – )
SWT-70
( – )
( – )
SS11V-06270
D3SBA60
FCU250V3.15A
STR-L472
15G561K
RF-5TK4R7
MP24GA
– 38 –
Specifications
DC 340V, 30W
10kΩ at 25°C
DC 390V, Secondary DC 15V, 12V, 7V
10kΩ at 25°C
27mH, AC 0.64A
4A, 600V
120µF, 450V
T3.15A, 250V
560V
4.7Ω, 5W
Output (Rated) 1W, 16 poles, 1 phase DC12V