RAS-M10UKV-E3, RAS-M13UKV-E3, RAS-M16UKV-E3
RAS-3M26YAV-E
To
C room
Connecting pipe
Thickness : 0.8mm
Ø12.7 :
RAS-M16UKV-E
Ø9.52 :
RAS-M10UKV-E
RAS-M13UKV-E
(Ø9.52)
TGc
Pressure
P
measurement
Gauge attaching port
Vacuum pump
connecting port
Accumulating
tank 1500cc
NOTE
• The maximum pipe length of this air conditioner is 50 m. The additional charging of refrigerant is unnecesary
because this conditioner is designed with charge-less specification.
• Connection of only one indoor unit is unavailable. Two or more indoor units should be connected.
Temp. measurement
T1
To
B room
(Ø9.52)
(Ø12.7)
TGb
TGa
Packed valve (Gas side)
(Ø12.7)
TS
Temp. measurement
T2
TCa
Indoor unit A
Evaporator
Cross flow fan
TA
Connecting pipe
Thickness : 0.8mm
Ø6.35
Sectional shape
of heat insulator
Muffler
Ø25 x 160L
TD
Compressor
DA220A2F-20L
TO
Propeller fan
Outdoor unit
– 42 –
To
To
C room
B room
(Ø6.35)
(Ø6.35)
Strainer
Packed valve
(Liquid side)
(Ø9.52)
TE
Refrigerant amount : 2.4kg (R410A)
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
Per 1 unit
Max. : 25m
Min. : 2m
Total
Max. : 50m
(Ø6.35)
Pulse modulating
valve at liquid side
(SKV18D26)