6-1. Operation Data
Outdoor Unit : RAS-4M27YAV-E
<Cooling>
Temperature
No. of
condition
operating
units
Indoor
Outdoor
1 unit
2 units
3 units
27 /19
35 / –
4 units
NOTES :
Model of Indoor unit 10 : RAS-M10UKV-E3, 13 : RAS-M13UKV-E3, 16 : RAS-M16UKV-E3
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bend.
(Thermistor thermometer)
(2) Connecting piping condition : 5 meters x 4 units (5m/each indoor unit)
Operating combination
(Unit)
A
B
C
D
10
–
–
–
13
–
–
–
16
–
–
–
10
10
–
–
13
10
–
–
16
10
–
–
13
13
–
–
16
13
–
–
16
16
–
–
10
10
10
–
13
10
10
–
16
10
10
–
13
13
10
–
16
13
10
–
13
13
13
–
16
16
10
–
16
13
13
–
16
16
13
–
16
16
16
–
10
10
10
10
13
10
10
10
16
10
10
10
13
13
10
10
16
13
10
10
13
13
13
10
16
13
13
10
16
16
10
10
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
0.8 to 1.0
9 to 11
0.7 to 0.9
8 to 10
0.6 to 0.8
7 to 9
0.8 to 1.0
10 to 12
0.8 to 1.0
10 to 12
0.8 to 1.0
10 to 12
0.8 to 1.0
10 to 12
0.7 to 0.9
9 to 11
0.7 to 0.9
9 to 11
0.8 to 1.0
11 to 13
0.8 to 1.0
11 to 13
0.8 to 1.0
11 to 13
0.8 to 1.0
11 to 13
0.8 to 1.0
11 to 13
0.8 to 1.0
11 to 13
0.8 to 1.0
11 to 13
0.8 to 1.0
11 to 13
0.8 to 1.0
12 to 14
0.8 to 1.0
12 to 14
0.9 to 1.1
12 to 14
0.9 to 1.1
12 to 14
0.9 to 1.1
12 to 14
0.9 to 1.1
12 to 14
0.9 to 1.1
12 to 14
0.9 to 1.1
12 to 14
0.9 to 1.1
12 to 14
0.9 to 1.1
12 to 14
– 43 –
Indoor
Outdoor
fan
fan
T2 (°C)
45 to 47
High
MED
46 to 48
High
MED
47 to 49
High
MED
47 to 49
High
MED
48 to 50
High
MED
49 to 51
High
MED
50 to 52
High
MED
51 to 53
High
MED
52 to 54
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
51 to 53
High
MED
Compressor
revolution
(rps)
22
35
45
42
46
50
54
58
62
60
60
60
60
60
60
60
60
60
60
61
61
61
61
61
61
62
62