Microcomputer - Toshiba RAS-M10UKV-E3 Service Manual

Split type
Table of Contents

Advertisement

11-2. Microcomputer

No.
Part name

Common
procedure
11-3. Outdoor Unit
No.
Part name

Common
1. Detachment
proceure
1) Stop operation of the air conditioner, and turn "OFF"
2) Remove the side panel. (Ø4 x 10 3 pcs.)
3) Remove the cord clamp. (Ø4 x 22 5 x 2=10 pcs.)
4) Remove the upper panel. (Ø4 x 10 6 pcs)
5) Remove the front panel. (Ø4 x 10 3 pcs.)
6) Remove the back panel. (Ø4 x 10 6 pcs)
7) Remove the air outlet panel. (Ø4 x 10 8 pcs)
Procedure
1) Turn the power supply off to stop the operation of
air-conditioner.
2) Remove the front panel.
• Remove the two fixing screws. (Ø4 x 14 )
3) Remove the electrical part base.
Procedure
the power breaker.
Disconnect the connecting cables and power cord from
the terminals.
– 102 –
Remarks
Replace the thermal fuse, terminal
block, microcomputer ass'y and the
P .C. board ass'y.
Remarks
Air outlet panel
Fan
guard
4
Front panel
Upper panel
Back panel
Side panel

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents