14. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
 
15. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.
If the tests run successfully, an expansion card may be conflicting with the diskette drive logic, or an expansion card may be faulty. Continue to the next
step.
If the tests fail, see
"Getting
 
16. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
 
17. Open the system. See
"Opening the
 
18. Reinstall one of the expansion cards you removed in
 
19. Close the system. See
"Closing the
 
20. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
 
21. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.
 
22. Repeat
step 16
through
step 21
If the problem is not resolved, see
 Troubleshooting an Optical Drive
 
Problem
 System cannot read data from a CD.
l
 Optical drive indicator does not blink during boot.
l
 
Action
 
CAUTION:
See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting
against electrostatic discharge.
 
1. Try using a different CD that you know works properly.
 
2. Enter the System Setup program and ensure that the drive's IDE controller is enabled. See "Using the System Setup Program" in your User's Guide.
 
3. Run the appropriate online diagnostic test. See
 
4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
 
5. Ensure that the optical drive interface cable is securely connected to the drive and the system board. To identify the connector on the system board, see
Figure A-3.
 
6. Ensure that a power cable is securely connected to the drive.
 
7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem is not resolved, see
 Troubleshooting a SCSI Tape Drive
 
Problem
 Defective tape drive.
l
 Defective tape cartridge.
l
Help."
System."
step
12. See
System."
until all expansion cards are reinstalled or one of the expansion cards causes the tests to fail.
"Getting
Help."
"Using Server Administrator
"Getting
Help."
"Installing an Expansion
Card" in "Installing System Components."
Diagnostics" in "Running System Diagnostics."

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents