To Clear Memory; Chime Function; Interior Function; Panic Keys - Regency 4720 Installation Manual

Control/communicator
Table of Contents

Advertisement

Regency
®
Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A)

To Clear Memory

16.4.2
To clear the alarm memory, press MUTE, MEM.
Note: The Alarm Memory can store alarms from all 80 zones. However, the alarms are displayed in order
by zone number, NOT in the order in which they occurred.

Chime Function

16.5
Press CHM while the panel is disarmed to toggle the Chime function.

Interior Function

16.6
Press INT to toggle the Interior zones. This key may be disabled once the system is armed. When the
Interior light is off, the Interior zones are not part of the system (sensors are ignored).
Note: If the Interior light will not turn on when armed, it indicates that one or more of the interior zones are not
ready.

Panic Keys

16.7
The POL, FIRE, and AUX keys will generate an alarm when held for one full second.
Note: The three panic keys (POL, FIRE, and AUX) must be disabled for commercial installations (UL
requirement).

Resetting an Alarm

16.8
To reset an alarm, enter your access code.

Signaling Duress

16.9
To signal duress, enter the duress trigger digits that have been programmed (1- or 2-digits) followed by
your access code.

Door Access

16.10
Note: Attempting door access during downloading could have the side-effect of scrambling the EEPROM. As a
prevention, notify end-users before downloading begins to make sure they avoid pressing the DOOR or
key or using an access card during downloading.

DOOR key (Commercial Touchpads Only)

16.10.1
Note: The Model 4720 is not listed for UL 294 access control systems.
1. Pressing DOOR, followed by your access code will cause the doorstrike output to activate.
2. If the High Security Access option was selected during programming, you must press DOOR
(display shows ENTER CODE A, then the High Security Access Code (Code 99). The display
will show ENTER CODE B. Enter your personal access code to activate the doorstrike.
3. The DOOR key (commercial models) or the CODE 2 key (residential models) may be used to
activate the Model 4150 Auxiliary Control Module. This may be done in one of two (2) ways:
(System Disarmed) - Enter the ID number of the auxiliary device being activated (1-8),
then press DOOR.
If the system is armed or the option was selected that you always need to use your access
code, you would follow the instructions for Step 1 then enter your access code after
pressing DOOR.
60
Revised 10/98