Bell Sounds; Keys - Regency 4720 Installation Manual

Control/communicator
Table of Contents

Advertisement

Regency
®
Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A)
The touchpad speakers will also beep when:
A key is pressed.
Someone has activated the zone display by pressing the BYPS, MEM, or STAT keys.
The zone display has been activated by an alarm or zone trouble condition (except silent alarms).
An incorrect keyswitch entry has been made. This tone is longer than the other beeps. There may
be a delay before it is sounded.

Bell Sounds

15.2.2
Fire Alarm Bell – A pulsing bell, sounded whenever there is a fire alarm (600 ms ON, 400 ms
OFF).
Emergency (Non-medical) Alarm Bell – A slowly pulsing bell, sounded whenever there is an
audible panic, gas, undefined, water, heat, cold, or local auxiliary alarm (2 seconds ON, 3
seconds OFF).
Intrusion Alarm Bell – A steady bell, sounded for burglary or tampering.

Keys

15.3
The Models 4660B, 4660C, and 4660R touchpads differ slightly. A few function keys are different and the
Model 4660R (residential) model has a "window" on the touchpad door that reveals the three panic keys
(POL, FIRE, and AUX).
The 4660B is intended for commercial use in installations not requiring door access. The DOOR key is not
active on the Model 4660B; pressing DOOR has no effect.
DLY
The DLY key toggles the zone status between delayed (No Delay light OFF) and Instant (No Delay
light ON). When the system is armed, if the No Delay light is ON, zones programmed for entry and
exit delay will be Instant—NOT delayed. If the zones are delayed (No Delay light OFF), and you
want them to be Instant, press DLY. You can NOT change instant zones to delayed while the system
is armed.
INT
The INT key controls whether or not zones programmed as Interior will respond to alarms when the
system is armed. (The INT and CHM keys toggle simultaneously.)
0 - 9 (Digits)
Use these keys any time you need to enter numerical information, such as access codes.
(Residential Only)
Nonfunctional key.
DOOR (Commercial Only)
The DOOR key is used in conjunction with an access code to activate doorstrikes to gain entrance
to areas programmed for authorized access only.
STAT
When the system is armed, and one or more zones is in a trouble condition, the STAT key turns on
the zone lights that correspond to these zones. (When the system is disarmed, these zone lights flash
automatically.) The STAT key can also be used to view system troubles (see Section 23: Trouble/
Error Messages).