52
Operation
4.
Adjust center of detection area with [Near] button or [Far] button in [MOVE X] and [MOVE Y] option.
5.
Select [RETURN] and exit [MOTION DET] menu with [Open] button or [Close] button.
,
Note
Even though Motion Detection function is set to [ON], Motion Detection function does not work in
the following cases.
>
When OSD Menu is being configured
>
When Pan/Tilt/Zoom function is working
>
When Pattern or Swing or Auto Pan is working
When motion is detected during Preset Tour or Group Tour, waiting time is automatically extended.
When motion is not detected any more, waiting time starts running.
When there are alarm inputs, waiting time is not extended even though motion is detected.
Communication
This setting is required to establish a connection between the system controller and the camera.
1.
Select [COMMUNICATION] option on the [SPECIAL] menu.
4
2.
Press [Open] or [Close] button.
3.
Set the below options.
Protocol: This item lets you set a protocol for RS-485 communication. Select the desired
protocol.
Baud Rate: Select the desired speed of communication between the system controller and the
camera. Confirm selected parameter to the baud rate of the system controller.
SAVE & EXIT: Select this option and then press [Open] or [Close] button to save the
communication settings and exit the setting menu.