Archgard DV - 520 User's Installation, Operation And Maintenance Manual

Archgard DV - 520 User's Installation, Operation And Maintenance Manual

Direct vent gas fireplace

Advertisement

WARNING: If the information in this manual is
not followed exactly, fire or explosion may result
causing property damage, personal injury or loss
of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Installer: Please leave this manual with the appliance owner for future reference
Direct Vent Gas Fireplace
For use with natural gas or propane*
U
O
M
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
DV - 520
I
SERS'
NSTALLATION
PERATION AND
AINTENANCE
This appliance may be installed in an
aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
*Conversion kit required for Propane use
M
ANUAL
200-0160
FEBRUARY 2005

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV - 520 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Archgard DV - 520

  • Page 1 DV - 520 Direct Vent Gas Fireplace For use with natural gas or propane* WARNING: If the information in this manual is not followed exactly, fire or explosion may result SERS’ NSTALLATION causing property damage, personal injury or loss of life.
  • Page 2: Requirements For The State Of Massachusetts

    Requirements for the state of Massachusetts 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 1.
  • Page 3: Table Of Contents

    CONTENTS Introduction General Information Appliance Description Dimensions and Clearances Installation Instructions 8 - 17 Operation Instructions 19 - 20 Maintenance Troubleshooting Instructions 22– 23 Wiring Diagrams Servicing 25 - 27 Replacement Parts Warranty Warranty Registration Form CAUTION Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
  • Page 4: Introduction

    DV - 520 INTRODUCTION Congratulations on choosing an Archgard fireplace. The Northfire DV-520 is one of the most advanced direct vent fireplaces available. It is solidly designed using the latest technology and manufactured to the highest quality. It is our aim to provide you with an appliance for many trouble-free years of reliable service.
  • Page 5: General Information

    - ANSI Z21.50b-1998/CSA 2.22b-M98, Vented Gas Fireplaces - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer.
  • Page 6: Appliance Description

    DV - 520 APPLIANCE DESCRIPTION FRONT VIEW Top Louvers (removable) Tempered glass front Removable bottom louvers for control access OPTIONAL KITS Optional Convection fan Blower Kit (120 Volt 60 Hz less than 2 Amps...
  • Page 7: Dimensions And Clearances

    DV - 520 DIMENSIONS AND CLEARANCES APPLIANCE DIMENSIONS 37 3/4” 16” 36” 2 3/4” 1/2” TOP VIEW FRONT VIEW SIDE VIEW CLEARANCES TO COMBUSTIBLES: BACK 0” to stand-offs SIDES 0” to stand-offs 0” to stand-offs BOTTOM 0” ADJACENT SIDE WALL 0” to side of faceplate...
  • Page 8: Installation Instructions

    DV - 520 INSTALLATION INSTRUCTIONS PRECAUTIONS • This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes. • Provide adequate clearance around air openings of the appliance. Never obstruct front openings.
  • Page 9 DV - 520 INSTALLATION INSTRUCTIONS Cont... Natural Gas Pressure Settings: The inlet supply or line pressure must be a minimum of 4.5” wc (1.1 kPa) and a maximum of 14” wc (3.5 kPa). The gas orifice has a #49 DMS drill size.
  • Page 10 4. DO NOT recess vent termination into walls, sidings or planters. 5. Vent terminations located below 7ft from grade level or anywhere that it can be a burn hazard to the public, such as patios and balconies, must be protected with an Archgard approved termination cage (part number C-1)
  • Page 11: Framing Dimensions

    DV - 520 FRAMING DIMENSIONS FRAMING DIMENSIONS 13⅜” 2” 41½” 31” 36” 16-¼” *32-¼” 16¼” 38” 28⅛” WHEN INSTALLING A SHELF OVER THE TOP OF REAR / TOP VENT MODEL DV520, THE FOLLOWING APPLIES: 1. Minimum height from floor to center of top vent must be 36”...
  • Page 12 • Minimum 2 ft (610 mm) straight length between bends. VENTING ABOVE ROOF OF THE HOUSE USING A VERTICAL TERMINATION Use Archgard, Simpson “Dura-Vent” or “Metal-fab” listed direct vent systems for all vertical vent termination applications (through the roof). Do not mix component parts.
  • Page 13 DV - 520 INSTALLATION INSTRUCTIONS Cont...
  • Page 14 3. Observe any local code restrictions, if any, regarding the installation of this type of gas appliance. 4. Observe the venting chart given in this manual. 5. Use vent spacers between the inside and outside vents at 3 ft (915 mm) intervals (Archgard vent kits only). 6. Never slope horizontal vents downwards.
  • Page 15 DV - 520 VERTICAL FLEXIBLE VENTING 1) With the fireplace in position, plumb the location in the ceiling and the roof for the vent. 2) Cut a 9 3/8” square hole in the ceiling. Frame around the opening. The 9 3/8” size opening ensures the required 1”...
  • Page 16 DV - 520 INSTALLATION INSTRUCTIONS Cont... HORIZONTAL VENT KIT COMPONENTS (TVK-1) Termination 7” and 4” flex vent lengths (compressed Fire-stop Cement Screws Sleeve Spring spacers VENT ASSEMBLY 4” exhaust vent with spring spacers Vent system assembled Cut sleeve to fit wall thickness...
  • Page 17: Installation Instructions

    DV - 520 INSTALLATION INSTRUCTIONS Cont... GLASS DOOR WARNING: Do not attempt to remove the glass door when the appliance is hot. WARNING: Do not abuse the glass such as striking or slamming shut Removing the Glass Door Remove the top louver by lifting off and open bottom louver.
  • Page 18 DV - 520 INSTALLATION INSTRUCTIONS Cont... LOGS AND EMBERS Rear Right log Front Center log Rear Left log Right Top log Embers LOG PLACEMENT 1) Place the Rear Right log on the locator pins that are on the back right of the main burner.
  • Page 19: Operation Instructions

    DV - 520 OPERATION INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING INITIAL OPERATION • Check that the appliance is properly vented and connected to the gas supply. • Check that the logs and branches are properly placed. • Check that all external parts, such as grills, door and faceplate are properly attached and fastened.
  • Page 20 DV - 520 OPERATION INSTRUCTIONS Cont.. LIGHTING INSTRUCTIONS (copy of instruction plate found on the unit) FOR YOUR SAFETY READ BEFORE WARNING: If you do not follow these instructions exactly, a fire of explosion may result causing property damage, personal injury or loss of life.
  • Page 21: Maintenance

    DV - 520 MAINTENANCE : Do not conduct maintenance on the appliance while it is operating or while it is still hot. CAUTION The appliance area should be kept clear and free from combustible materials, gasoline and other flam- mable vapors and liquids.
  • Page 22: Troubleshooting Instructions

    DV - 520 TROUBLESHOOTING Please check to make sure the instructions are followed exactly before attempting troubleshooting of the appliance. WARNING: Troubleshooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician.
  • Page 23 DV - 520 TROUBLE SHOOTING Cont... SYMPTOM ACTION The main burner does not 3. Check that the remote control or the wall switch is turned on. turn on with the pilot lit. 4. Check for weak pilot flame. If flame is weak, check gas supply, Cont...
  • Page 24: Wiring Diagrams

    DV - 520 WIRING DIAGRAMS VALVE CONNECTIONS SPARK ELECTRODE PILOT BURNER THERMOCOUPLE THERMOPILE PILOT ON/OFF SWITCH ASSEMBLY To SPARKER...
  • Page 25: Servicing

    SERVICING SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the authorized Archgard dealer that you purchased the appliance from and provide them with details of the problem and the installation information that the installer filled in at the back of the manual.
  • Page 26 DV - 520 SERVICING Cont... CHANGING MAIN BURNER ORIFICE • Remove the glass door, log branches and the front log. • Unscrew the 2 screws holding the burner to the floor. • Lift the burner up and away from the orifice cap.
  • Page 27: Servicing

    In the event your glass cracks or breaks, it must be replaced by the exact same size and mate- rial. It is made from high temperature clear TEMPERED material. See replacement parts list and contact your nearest Archgard dealer. Refer to page 17 for removal details. •...
  • Page 28: Replacement Parts

    DV - 520 REPLACEMENT PARTS FOR DV - 520 ITEM # DESCRIPTION UNIT OWNER’S MANUAL 200-0079 LATCH, DOOR 1 11/16” X 1 3/16” 300-0034 ORIFICE CAP #49 (NATURAL GAS) 301-0050 ORIFICE CAP #57 (PROPANE GAS) 301-0068 SPEED CONTROL (KBMS-13BV) c/w KNOB...
  • Page 29: Warranty

    This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the original purchaser of an Archgard gas burning fireplace (s) that the product will be free of defects in materials and workmanship under normal use and service, for a “lifetime”.
  • Page 30 DV - 520 NOTES...
  • Page 31: Warranty Registration Form

    POSTAG WARRANTY REGISTRATION RCHGARD NDUSTRIES 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSED DV - 520 Model # : Serial #: Date Installed: yyyy Name: Address: City: State/Prov: ZIP: Phone: ( _____ ) Dealer's Name &...
  • Page 32 DV - 520...
  • Page 33 Archgard Industries Ltd. 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.com...

This manual is also suitable for:

520-dvt15n

Table of Contents