Archgard Marquis DVR-38 User's Installation, Operation And Maintenance Manual

Marquis 38 series direct vent gas fireplace for use with natural gas or propane

Advertisement

WARNING: If the information in this manual is not
followed exactly, fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use any
phone in your building.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Installer: Please leave this manual with the appliance owner for future reference
Direct Vent Gas Fireplace
For use with Natural Gas or Propane*
U
SERS'
O
M
This appliance may be installed in an after-market,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
*Conversion Kit Required for Propane Use
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
MARQUIS 38
DVT-38 & DVR-38
I
NSTALLATION
PERATION and
AINTENANCE
M
ANUAL
200-0044
MARCH 2005

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Marquis DVR-38 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Archgard Marquis DVR-38

  • Page 1 Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installer: Please leave this manual with the appliance owner for future reference MARQUIS 38 DVT-38 & DVR-38 Direct Vent Gas Fireplace For use with Natural Gas or Propane* SERS’...
  • Page 3: Table Of Contents

    Marquis 38 Introduction General Information Appliance Description and Dimensions Framing Dimensions Clearance to Combustibles Possible Fireplace Locations Venting Instructions Gas Connections Glass Door Instructions Log Placement Instructions Fan and Valve Diagrams Initial Start Up Maintenance Troubleshooting Servicing Replacement Parts List...
  • Page 4: Introduction

    Marquis 38 Thank you for purchasing the Marquis DV-38 Direct Vent Built-in Gas Fireplace. The Marquis DV-38 is one of the most advanced gas fireplaces on the market. It is designed using the latest technology and manufactured to the highest quality.
  • Page 5: General Information

    Marquis 38 APPLIANCE CERTIFICATION This appliance is listed by Warnock Hersey for use in both the United States and Canada. It is tested and certified to the following US and Canadian gas appliance standards. - ANSI Z21.50-1996 / CGA 2.22-M96, Vented Gas Fireplace and Heaters - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes.
  • Page 6: Appliance Description And Dimensions

    Marquis 38 APPLIANCE DESCRIPTION & DIMENSIONS FRONT VIEW TOP LOUVERS GLASS DOOR CONVECTION FAN SPEED CONTROL (Optional) GAS VALVE APPLIANCE DIMENSIONS 1/4” 38” 23-1/2” 3” 6” 39-3/4” FRONT VIEW SIDE VIEW TOP VIEW * Except for the vent connector locations, the rear vented DV-38 and top vented DVT-38, have the...
  • Page 7: Framing Dimensions

    Marquis 38 FRAMING DIMENSIONS 16-¼” *32-¼” 38” 16-¼” 38” 38-½” FRAMING DIMENSIONS 2” 37” WHEN INSTALLING A SHELF OVER THE TOP OF REAR / TOP VENT MODEL DV38, THE FOLLOWING APPLIES: 1. Minimum height from floor to center of top vent must be 37”...
  • Page 8: Clearance To Combustibles

    Marquis 38 CLEARANCE TO COMBUSTIBLES PRECAUTIONS • This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes. • Provide adequate clearance around air openings of the appliance. Never obstruct front openings.
  • Page 9: Possible Fireplace Locations

    Marquis 38 POSSIBLE FIREPLACE LOCATIONS LOCATING GAS FIREPLACE This appliance must be installed in any location that is free of plumbing, electrical wiring and heating or air conditioning ducts. Select a location that is accessible for venting. See PAGE “ALLOWABLE TERMINATION LOCATIONS”.
  • Page 10: Vent Termination

    Marquis 38 VENT TERMINATION 1. See “ALLOWABLE TERMINATION LOCATIONS” diagram (page 13) to establish a suitable vent termination location. 2. In heavy snowfall areas make sure vent termination is located where it can not be blocked by snow from snow removal equipment.
  • Page 11 Marquis 38 VENTING INSTRUCTIONS VENTING CHART (FOR TOP VENTED APPLIANCES ONLY) 10 ft 7 ft 37” 31” 1 ft • Chart is for one 90° bend, with 1/4” vertical raise minimum per foot of horizontal length. • For each additional 90° or two 45°, add 1ft of vertical height.
  • Page 12 Marquis 38 VENTING INSTRUCTIONS RESTRICTOR PLACEMENT “FOR ABOVE 7 FOOT VERTICAL RISE VENTED APPLICATIONS ONLY” WARNING: These restrictors are only to be installed in the vent system if the vent exceeds 7’ in vertical height, *Restrictor Number 1 below is required. Installing them under any other circumstances may cause hazardous venting conditions and may result in personal injury, property damage or death.
  • Page 13 Marquis 38 VENTING INSTRUCTIONS Cont...
  • Page 14: Gas Connections

    Marquis 38 Please follow the venting instructions as strictly as possible to obtain the best performance from the appliance. GAS CONNECTIONS Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the gas type you are using. The gas type markings are located on the certification label and also on the appliance’s gas valve.
  • Page 15: Glass Door Instructions

    Marquis 38 GLASS DOOR INSTRUCTIONS GLASS DOOR WARNING: Do not attempt to remove the glass door when the appliance is hot. Removing the Glass Door Remove the top and bottom louvers. There are two latches under the firebox. Undo the latches, swing the bottom of the door away from the appliance and then lift the door off the top retaining tabs.
  • Page 16: Log Placement Instructions

    Marquis 38 LOG PLACEMENT INSTRUCTIONS PLACEMENT OF LOGSET, FIBER COALS & EMBER WOOL • Place the back log at the back of the burner tray as shown, behind the two tabs on the burner tray. • Place the front log on top of the burner as shown. The metal tabs protruding from the bottom of the log straddle the side of the burner top.
  • Page 17: Wiring Diagram

    Marquis 38 FAN & VALVE WIRING DIAGRAM/INSTRUCTIONS ELECTRICAL CONNECTIONS (for optional convection fan kit FK 36/38 only) • Install the fan first. Remove the lower louvers and gently place the bottom front lip of the blower mounting bracket into the opening. Slide the blower assembly into the bottom of the fireplace.
  • Page 18: Initial Start Up

    Marquis 38 INITIAL START UP INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING INITIAL OPERATION • Check that the appliance is properly vented and connected to the gas supply. • Check that the logs and branches are properly placed. • Check all external parts, such as grills, door and control cover are properly attached and fastened.
  • Page 19: Start-Up Procedure

    Marquis 38 INITIAL START UP INSTRUCTIONS START-UP PROCEDURE Set the thermostat, if present, to the lowest level. Press slightly and turn the control knob clockwise to the OFF position and wait 5 minutes; thus allowing any gases to escape which may have accumulated in the combustion chamber.
  • Page 20: Cleaning The Appliance

    Marquis 38 CAUTION : Only conduct maintenance on a cold appliance. CLEANING THE APPLIANCE The exterior painted surfaces, glass and gold trims may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner. Regularly, •...
  • Page 21: Troubleshooting

    Marquis 38 Please check to make sure the instructions are followed exactly before attempting troubleshooting of the appliance. WARNING: Troubleshooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician. SYMPTOM Pilot will not light after pressing the sparker many times.
  • Page 22 Marquis 38 SYMPTOM The main burner does not turn on with the pilot lit. Cont... The main burner shuts off when the appliance is warm. Sooty deposits on the glass door. Sharp blue flames with flames lifting off the burner at the ends.
  • Page 23: Servicing Under Warranty

    Marquis 38 WARNING: Servicing of this appliance must be conducted by a qualified service technician. Improper servicing, adjustment or alteration of this appliance may cause property damage, personal injury or loss of life. All servicing should be conducted with the appliance cold.
  • Page 24: Changing Main Burner Orifice

    Marquis 38 CHANGING MAIN BURNER ORIFICE • Remove the glass door, log set and the burner. • Use a 5/8” wrench to loosen the compression fitting to the cap orifice. • Use two 1/2” wrenches to loosen and remove the cap orifice.
  • Page 25: If Your Glass Breaks

    Marquis 38 CONVERTIBLE PILOT ORIFICE The pilot assembly is convertible to the type of gas being used, simply unscrew the body by using a 7/16” (11 mm) wrench turn a 1/4 open then push the small metal tab across to the other side of the body and retighten.
  • Page 26: Servicing

    Marquis 38 REPLACING VALVE PLATE ASSEMBLY Replacing Gas Component Assembly • Disconnect electricity to the appliance. (If equipped with Optional Fan Kit) • Remove the glass door and the logs. (See installation section pages 11 and 12) • Remove the burner tray by loosening and removing the two mounting screws located on the sides of the burner.
  • Page 27: Replacement Parts List

    Marquis 38 Replacement Parts list for Marquis DV-38D & DVT38D Item # 200-0044 OWNER’S MANUAL, MARQUIS DV-38D & DVT38D 301-0068 ORIFICE CAP, DRILL TO #56 (PROPANE GAS) 301-0068 ORIFICE CAP, DRILL TO #48 (NATRAUL GAS) 305-0013 FAN SPEED CONTROL (RHEOSTAT) FOR OPTIONAL FAN KIT FK-36/38 305-0021 FAN THERMODISK 110 DEG.
  • Page 28: Warranty

    This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the original purchaser of an Archgard gas burning fireplace(s) that the product will be free from defects in materials and workmanship under normal use and service, for a “lifetime”.
  • Page 30: Warranty Registration

    WARRANTY REGISTRATION ARCHGARD INDUSTRIES LTD. MISSION, B.C. CANADA FOLD DOWN AT LINE & TAPE CLOSED Model # : Name & Address: City: Dealer's Name & Address: City: Installer's Name & Address: City: Why did you choose this product? Thank you for purchasing our product and filling out this warranty card. 7116 BEATTY DRIVE V2V 6B4 FOLD DOWN AT LINE...
  • Page 31 Archgard Industries Ltd. 7116 Beatty Drive Mission, British Columbia, Canada V2V 6B4 Telephone: 604-820-8262 Telephone Toll Free: 877-820-9800 Fax: 604-820-8881 Fax Toll Free: 866-820-2802 Website: www.archgard.com...

This manual is also suitable for:

Marquis dvt-38Dvr-38Dvt-38

Table of Contents