Archgard DVR 36-H User's Installation, Operation And Maintenance Manual

Direct vent gas fireplace

Advertisement

f i r e - p a r t s . c o m
WARNING: If the information in this manual is not
followed exactly, fire or explosion may result
causing property damage, personal injury or loss
of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Installer: Please leave this manual with the appliance owner for future reference
DVR 36-H / DVT 36-H
Direct Vent Gas Fireplace
For use with natural gas or
U
O
M
*Conversion kit required for Propane use
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
C
propane*
I
SERS'
NSTALLATION
PERATION AND
AINTENANCE
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a
certified kit is used.
US
Master Contract: 214018
M
ANUAL
200-0052
APRIL 2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVR 36-H and is the answer not in the manual?

Questions and answers

Summary of Contents for Archgard DVR 36-H

  • Page 1 DVR 36-H / DVT 36-H Direct Vent Gas Fireplace For use with natural gas or propane* f i r e - p a r t s . c o m WARNING: If the information in this manual is not SERS’...
  • Page 2 f i r e - p a r t s . c o m...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction General Information Appliance Description and Dimensions Framing Dimensions Clearance to Combustibles Possible Fireplace Locations Venting Instructions Gas Connection Glass Door Removal f i r e - p a r t s . c o m Log Placement Fan and Valve Diagrams Initial Start-Up Maintenance...
  • Page 4: Introduction

    Northfire 36-H INTRODUCTION Thank you for purchasing the NorthFire-DVR36-H / DVT36-H Direct Vent Built-in Gas Fireplace Heater. The NorthFire-DV36-H is one of the most advanced gas fireplace heaters on the market. It is designed using the latest technology and manufactured to the highest quality. Some of the many features are: ∗...
  • Page 5: General Information

    - ANSI Z21.50-1996 / CGA 2.22-M96, Vented Gas Fireplace and - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes. Please contact Warnock Hersey or Archgard Industries Ltd., if you have any questions regarding the certification of this appliance. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer.
  • Page 6: Appliance Description And Dimensions

    Northfire 36-H APPLIANCE DESCRIPTION & DIMENSIONS FRONT VIEW TOP LOUVRES GLASS DOOR CONVECTION FAN SPEED CONTROL f i r e - p a r t s . c o m GAS VALVE APPLIANCE DIMENSIONS 3/4” 36 1/4” 23 1/2” 3 1/2” 5 1/4”...
  • Page 7: Framing Dimensions

    Northfire 36-H FRAMING DIMENSIONS FRAMING DIMENSIONS 16” f i r e - p a r t s . c o m *31” 36 1/4” * If more rigidity is required, a stud may be added to the back of the top nailing flange after the fireplace is installed.
  • Page 8: Clearance To Combustibles

    Northfire 36-H CLEARANCE TO COMBUSTIBLES PRECAUTIONS • This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes. • Provide adequate clearance around air openings of the appliance. Never obstruct front openings. •...
  • Page 9: Possible Fireplace Locations

    Northfire 36-H POSSIBLE FIREPLACE LOCATIONS LOCATING GAS FIREPLACE This appliance must be installed in a location that is free of plumbing, electrical wiring and heating or air conditioning ducts. Select a location that is accessible for venting. See APPENDIX A. ALLOWABLE TERMINATION LOCATIONS.
  • Page 10: Venting Instructions

    7. Maintain at least an upward slope of 1” for every 1 ft of horizontal run on the rear vented models. 8. Terminate the vent with a vent termination supplied by Archgard Industries Ltd. 9. Support horizontal running vents every 3 ft to prevent it from sagging.
  • Page 11 Northfire 36-H VENTING INSTRUCTIONS Cont... VENTING Cont... VENTING CHART (FOR TOP VENTED APPLIANCES ONLY) 10 ft Venting in this area requires a vent restrictor plate #1. 7 ft Maximum Hori- zontal run for Rear Vent is 20” 36” from the back of 30”...
  • Page 12 Northfire 36-H VENTING INSTRUCTIONS Cont... f i r e - p a r t s . c o m...
  • Page 13 Archgard System In the Archgard system the restrictors are placed on the exhaust outlet on the appliance. Simpson Duravent With Simpson Duravent locate the restrictor in the exhaust section fitting into the formed lip.
  • Page 14: Gas Connection

    Northfire 36-H GAS CONNECTION INSTRUCTIONS GAS CONNECTIONS Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the gas type you are using. The gas type markings are located on the certification label and also on the appliance’s gas valve. Provide adequate clearance for proper installation and checking of the gas connections.
  • Page 15: Glass Door Removal

    Northfire 36-H GLASS DOOR INSTRUCTIONS GLASS DOOR WARNING: Do not attempt to remove the glass door when the appliance is hot. Removing the Glass Door Remove the top and bottom louvers. There are two buckle latches securing the door frame in place (two hooks above the door and two buckle latches below the door).
  • Page 16: Log Placement

    Do not add any materials to the burner, other than the type and amount provided by Archgard. f i r e - p a r t s . c o m 4. Place the “Y” branch as shown. The back log has a notch to accommodate the branch. There is also a tab on the burner to locate the branch.
  • Page 17: Fan And Valve Diagrams

    Northfire 36-H FAN & VALVE WIRING DIAGRAM/INSTRUCTIONS ELECTRICAL CONNECTIONS (for optional convection fan kit FK 36/38 only) • Install the fan first. Remove the lower louvers and gently place the bottom front lip of the blower mounting bracket into the opening. Slide the blower assembly into the bottom of the fireplace. Rotate the blower into position.
  • Page 18: Initial Start-Up

    Northfire 36-H INITIAL START-UP INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING INITIAL OPERATION • Check that the appliance is properly vented and connected to the gas supply. • Check that the logs and branches are properly placed. • Check all external parts, such as grills, door and control cover are properly attached and fastened.
  • Page 19 Northfire 36-H INITIAL START UP INSTRUCTIONS OPERATION INSTRUCTIONS Cont.. Cont... START-UP PROCEDURE Set the thermostat, if present, to the lowest level. Set the flame adjustment knob to the HI position. Press slightly and turn the control knob clockwise to the OFF position and wait 5 minutes;...
  • Page 20: Maintenance

    Northfire 36-H MAINTENANCE CAUTION : Only conduct maintenance on a cold appliance. CLEANING THE APPLIANCE The exterior painted surfaces, glass and gold trims may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner. Regularly, •...
  • Page 21: Troubleshooting

    Northfire 36-H TROUBLESHOOTING Please check to make sure the instructions are followed exactly before attempting troubleshooting of the appliance. WARNING: Troubleshooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician. SYMPTOM ACTION Pilot will not light after pressing the...
  • Page 22: Trouble Shooting

    Northfire 36-H TROUBLE SHOOTING Cont... SYMPTOM ACTION The main burner does not turn on with 3. Check to make sure the thermostat is set high enough to turn on the appliance. the pilot lit. Cont... 4. Check that the remote switch or the thermostat is turned on. 5.
  • Page 23: Servicing

    SERVICING SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the Archgard authorized dealer which you have purchased the appliance from and provide him with details of the problem and the installation information which the installer has fill out at the back of the manual.
  • Page 24 Northfire 36-H SERVICING Cont... CHANGING MAIN BURNER ORIFICE • Remove the glass door, log set and brick panels (if used) • Remove the burner by removing the screws on each side of the burner. • Use a 5/8” wrench to loosen the compression fitting to the cap orifice. •...
  • Page 25 WRENCH (HERE) the other side of the body and retighten. Call your local Authorized Archgard Dealer to purchase the correct fuel conversion kit for your gas appliance. f i r e - p a r t s . c o m...
  • Page 26 Northfire 36-H SERVICING Cont... REPLACING VALVE PLATE ASSEMBLY • Disconnect electricity to the appliance. (If equipped with Optional Fan Kit) • Remove the glass door and the logs. See glass door instructions. • Remove the burner tray by loosening and removing the two mounting screws located on the sides of the burner.
  • Page 27: Replacement Parts List

    Northfire 36-H Replacement Parts list for NORTHFIRE DV36-H / DVT36-H Item # Item Description Unit 200-0052 OWNER’S MANUAL, NORTHFIRE DV36H & DVT36H 301-0068 ORIFICE CAP, DRILL TO #44 (NATURAL GAS) 301-0068 ORIFICE CAP, DRILL TO #55 (PROPANE GAS) 307-0016 GLASS, CERAMIC 16.150 X 28.843 305-0013 FAN SPEED CONTROL (RHEOSTAT) (FOR OPTIONAL FAN KIT FK-36/38) 305-0021...
  • Page 28: Warranty

    Problem Description ❖ NOTE: Warranty may be void if work is carried out by an unqualified person (s). Only original Archgard parts may be used. Please consult your Archgard dealer or representative if in doubt about a replacement part (s).
  • Page 29: Warranty Registration Card

    Postage WARRANTY REGISTRATION ARCHGARD INDUSTRIES LTD. 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE f i r e - p a r t s . c o m FOLD DOWN AT LINE & TAPE CLOSED Northfire 36 - H...
  • Page 30 f i r e - p a r t s . c o m...
  • Page 31 Archgard Industries Ltd. 7116 Beatty Drive Mission, B.C. V2V 6B4 f i r e - p a r t s . c o m Canada Telephone: (604) 820 - 8262 Fax: (604) 820 - 8881 Telephone Toll Free: 1 - 877 - 820 - 9800 Fax Toll Free: 1 - 866 - 820 - 2802 Website: www.archgard.com...

This manual is also suitable for:

Dvt 36-h

Table of Contents