The Centralized Configuration Screen; Table 33 Zyxel Centralized Configuration Specifications - ZyXEL Communications NXC-8160 User Manual

Business wlan controller
Hide thumbs Also See for NXC-8160:
Table of Contents

Advertisement

Chapter 7 Advanced Settings
Table 32 SNMP Traps (continued)
TRAP TYPE
RADIUS Redundancy Selection
Changed <ESSID><#of
RADIUS>to<# of RADIUS>
No RADIUS <ESSID>
Configured and connected
APs of channel [<channel
number>]
AP <ap number in hex base>
has been connected
AP <ap number in hex base>
has been disconnected
Reference Host is up
Reference Host is down
Standby Switch is up
Standby Switch is down
Inactive - Reference Host
is down
Inactive Standby Switch -
Main Switch is up
Main Switch is active again This trap is sent when the main NXC-8160 changes status from
Failure detected in Main
Switch - Switching Over

7.5 The Centralized Configuration Screen

Click Advanced > Centralized Configuration to open this screen. Centralized Configuration
allows you to configure multiple NXC-8160 devices (a collection known colloquially as
slaves or member devices) through a single NXC-8160 device (known as the master
controller). The devices must be able to communicate with one another.

Table 33 ZyXEL Centralized Configuration Specifications

Maximum number of centralized
configuration members
Centralized Configuration Member
Models
Master Controller
Member Controllers
82
DESCRIPTION
This trap is sent when the RADIUS selection has been changed
from one server to another, and includes the ESSID, the
number of the previous server and the number of the new
server.
This trap is sent when the last RADIUS server failed and
includes the ESSID.
This trap provides a summary of all APs and their status. This
trap is typically sent after an event of AP removal or connection
from/to the switch.
This trap is typically sent after an event of connecting an AP to
the switch.
This trap is typically sent after an event of disconnecting an AP
from the switch.
This trap is sent when the reference server is up and active.
Sent by the main NXC-8160.
This trap is sent when the reference server is down. Sent by the
main NXC-8160.
This trap is sent when the standby NXC-8160 is up and active.
This trap is sent when the standby NXC-8160 is down.
This trap is sent when the reference server is down, and hence
the main NXC-8160 becomes inactive.
This trap is sent when the main NXC-8160 becomes active
again and hence the standby NXC-8160 becomes inactive
(switch over).
inactive to active and regains the main NXC-8160 status.
This trap is sent when the main NXC-8160 is about to go down
and the standby NXC-8160 is becoming Active.
6
This device must be compatible with ZyXEL centralized
configuration implementation.
This is the device through which you manage the member
devices.
These are the devices being managed by the master device.
NXC-8160 User's Guide