Tp Cable Termination And Recommendations - Extron electronics XTP T USW 103 User Manual

Three input switcher with an integrated xtp transmitter
Hide thumbs Also See for XTP T USW 103:
Table of Contents

Advertisement

TP Cable Termination and Recommendations

Use the following pin configurations for twisted pair cables.
Pins:
12345678
Insert Twisted
Pair Wires
RJ-45
Connector
Figure 5.
Supported cables
The XTP T USW 103 is compatible with CAT 5e, 6, 6a, and 7 shielded twisted pair (F/UTP,
SF/UTP, and S/FTP) and unshielded twisted pair (U/UTP) cable.
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable
to link the XTP products.
To ensure FCC Class A and CE compliance, STP cables and STP connectors are
required.
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances up
to 330 feet (100 m) and reduce transmission errors.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000
XTP DTP 24P/1000 Plenum 1000' (305 m) spool
XTP DTP 24 Plug
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard (see figure 5).
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points
are required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTE: When using CAT 5e or CAT 6 cable in bundles or conduits, consider the
following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 m, where cables are straightened, aligned,
and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook and loop fasteners.
Separate twisted pair cables from AC power cables.
Straight-through Cable
T568A
(for connection to a switch, hub, or router)
Pin
Wire color
TIA/EIA-T568A
1
White-green
White-orange
Pin
Wire Color
Pin
2
Green
Orange
1
White-green
1
3
White-orange
White-green
2
Green
2
4
Blue
Blue
3
White-orange
3
5
White-blue
White-blue
6
4
Orange
Blue
Green
4
7
White-brown
White-brown
5
White-blue
5
8
Brown
Brown
6
Orange
6
7
White-brown
7
8
Brown
8
TP Cable Termination
Non-Plenum 1000' (305 m) spool
Package of 10
T568B
Wire color
TIA/EIA-T568B
Wire Color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
XTP T USW 103 • Installation