Maintenance - Titan SF2541 Safety And Operating Manual

10” mitre saw
Table of Contents

Advertisement

Fig 17

MAINTENANCE

Warning: Before making any adjust
ment, maintenance to the saw, make
sure that it is disconnected from mains
supply.
When all the adjustments, settings or
maintenance have been done, make sure that
all keys and wrenches have been removed
and that all screws, bolts and other fittings
are securely tightened.
PRECISION SETTING OF ANGLES
While the machine has been factory set, it is
advisable that the 0
and the 90
O
perpendicular setting of the tilt be
checked, as these positions may have moved in
transit.
To confirm the 0
O
O
rotary table at 0
and tighten the rotary table lock
handle. Check that the angle between the straight
guide and the blade is 90
square (A, not supplied). (see Fig13). If the angle
requires adjustment, loosen two straight guide
clamp screws (as shown in Fig4) and align the
straight guide against the engineers square.
Retighten the clamp screws.
Similarly check that the angle of the blade to the
face of the table is 90
suitable slotted screwdriver, loosen the 90
(See Fig 12 No 1), set to the correct position and
re tighten the screw.
The 45
O
can also be adjusted. First check the
angle with a 45
O
set square (not provided and see
Fig 15). To adjust, loosen the 45
12 No 2), set to correct angle and re tighten the
screw.
Note:
The position of bevel scale pointer may have
moved in transit or after use. Use a screwdriver
to adjust it if necessary.
CHANGING THE SAW BLADE
Warning: Disconnect the saw from the
power supply.
Loosen and remove the blade securing bolt and
outer flange with the spanners provided. (See fig
16)
O
setting of the rotary table
rotary table setting, set the
O
using an engineers
O
. If it is not vertical, use a
O
screw (See Fig
O
screw