#set_output_name Command
The #set_output_name command provides a name to the selected output. For
example, "Output 1" could be renamed as "HDDisplay". The maximum string
length for param2 is 15 characters. Special characters and spaces are not
permitted. If required, use the underscore character ("_") to separate characters.
Syntax:
#set_output_name param1 param2
Parameters:
param1
param2
Example:
#set_output_name 3 display_3
display_3 is assigned to output 3
#show_temp
The #show_temp command provides temperature information for the matrix.
Syntax:
#show_temp
Parameters:
None
Example:
#show_temp
Temperature near main power supply is 45
Temperature near cross point is 53
Temperature near power supply input board is 47