#set_input_name Command
The #set_input_name command provides a name to the selected input.
For example, "Input 1" could be renamed as "Computer 1". The maximum string
length for param2 is 15 characters. Special characters and spaces are not
permitted. If required, use the underscore character ("_") to separate characters.
Syntax:
#set_input_name param1 param2
Parameters:
param1
param2
Example:
#set_input_name 5 computer1
computer1 is assigned to input 5
#set_ir Command
The #set_ir set the IR channel for the matrix. The associated DIP switch settings
for the IR remote control unit are returned. See page 13 for details on setting the
IR channel for the IR remote control.
Syntax:
#set_ir param1
Parameters:
param1
Example:
#set_ir 2
RMT_IR - SW1=0,SW2=1
TELNET / RS-232 COMMANDS
Input
Name
Channel
46