2.9. Technical specification of optional PORT1

Expansion port RS232

Power supply
Environment
Standards
RS232 specifications
(EN 1434)

Expansion port RS485

Power supply
Environment
Standards
RS485 specifications
(EN 1434)
External or internal power supply of module Expansion port RS485/RS422 can be
made by wiring jumpers J2 and J3 on this module. If external power supply of the module is
required, jumpers J2 and J3 must be connected to pins 2 - 3. Internal power supply is made
by connecting pins 1 - 2 with jumpers J2 and J3.
Interface behavior of module Expansion port RS485/RS422 can be made by wiring
jumpers J4, J5 and J6 on this module. If RS485 is required, jumpers J4 and J5 must be
connected and jumper J6 disconnected. If RS422 is required, jumpers J4 and J5 must be
disconnected and jumper J6 connected.
Jumper placement can be seen in the picture below (module Expansion port
RS485/RS422 from TOP layer). We recommend that internal power supply is only chosen
in the event that it is not possible to ensure external power supply. If internal power supply is
chosen, converter RS485/RS422 is not galvanic separated.
21
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
Expansion port RS232
Expansion port RS485
External
Internal
Supply power
Supply current
Operating temperature
Storage temperature
Emission
Immunity
Safety
Max. devices (each 1,5 mA)
Max. bit rate
Short circuit strength
Max. total cable length
(300Bd, 200nF/km)
Internal
Operating temperature
Storage temperature
Emission
Immunity
Safety
Max. operating bus current
Max. bit rate
Max. overvoltage
Max. total cable length
(300Bd, 200nF/km)
DESCRIPTION
....
-20 .. +55 C
-20 .. +85 C
EN 55022/B
ETS 300 342
EN 60950
15 mA
230400 bps
±30 V
20 m
RS485
RS422
+10 .. +30 V
....
Max. 1 W
Max. 4 mA
-20 .. +55 C
-20 .. +85 C
EN 55022/B
ETS 300 342
EN 60950
256
38400 bps
Permanent
1200 m