UCR11 v2
CDMA/UMTS router
USER'S MANUAL
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UCR11 v2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lucom UCR11 v2

  • Page 1 UCR11 v2 CDMA/UMTS router USER’S MANUAL LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 2 Source codes under GPL license are available free of charge by sending an email to: info@conel.cz. Conel s.r.o., Sokolska 71, 562 04 Usti nad Orlici, Czech Republic Manual issued in CZ, January 8, 2014 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 3: Table Of Contents

    7.2 Technical parameters of UMTS module ..... . LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 4 7.6 Technical parameters of expansion port ..... . 8 Recommended literature 9 Possible problems 10 FAQ 11 Customers support LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 5: List Of Figures

    Router connection ........LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 6: List Of Tables

    Technical parameters I/O port ......LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 7: Safety Instruction

    It is recommended that you should create an appropriate copy or backup of all the im- portant settings that are stored in the memory of the device. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 8: Product Disposal Instructions

    MUST NOT be mixed with other commercial waste for disposal. Check the terms and condi- tions of your supplier for disposal information. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 9: Router Description

    R-SeeNet. Examples of possible applications mobile office fleet management security system telematic telemetric remote monitoring vending and dispatcher machines LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 10: Contents Of Package

    Two expansion ports: RS232, RS485/422, MBUS, ETHERNET, CNT, SWITCH, WIFI, WMBUS or SDH. Separation columns for mounting expansion boards are included. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 11: Router Design

    Other UCR11 v2F SL UCR-11-v2 Full version in the metal box Table 2: Delivery identification Figure 3: Label UCR11 v2F-01 SL LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 12: Version Of Firmware Module

    Table 3: Version of firmware module Example of trade name: UCR11 v2F-01 SL Example of type name: UCR-11-v2F SL ver. 01 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 13: Ordering Codes

    fitted with a diversity antenna for CDMA on customer’s request. In this case, it is necessary to write capital letter D behind two digits indicating the operator in ordering code. Example: UCR11 v2F-01D ETH RS485 set. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 14: Basic Dimensions Of Metal Box

    fit a lightening conductor, LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 15: Space Around Antennas

    – With data cables they mustn’t carry cables with reticular tension 230 V/50 Hz. – All signals to sensors must be twisted pairs. Figure 6: Cable routing LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 16: Space In Front Of Connectors

    For correct function of the router we recommend to use in the switch-board earth-bonding distribution frame for grounding of power supply of router, data cables and antenna. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 17: Default Position Of Din Holder

    CKD2 holder hitched to the DIN rail get out of this rail and then fold out the top part of the router away from the DIN rail. Figure 9: Removing from the DIN rail LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 18: Front Panel Ucr11 V2F Sl

    Holder for the first SIM card. SIM2 — Holder for the second SIM card. Table 5: Front panel description Figure 10: Front panel UCR11 v2F SL LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 19: Router Status Indication

    SIM card 3 is active (CDMA) Table 6: Router status indication State indication of WAN LED is updated every 10 seconds. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 20: Power Connector Pwr

    Circuit example: Figure 13: Connection of power supply The positive pole VCC is marked by a red socket on the power. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 21: External Antenna

    SMA connector on the front panel of the router (see figure below). Figure 15: Connecting of the antenna Diversity antenna improves radio features of the router at low signal strength. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 22: Ejected Sim Holder

    — — — — RXD- Receive Data – negative pole Input/Output — — — — Table 8: Connection of Ethernet connector LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 23: Ethernet Connector

    Ethernet cable plug into the RJ45 connector labeled as ETH (see figure below). Figure 18: Connection of ethernet cable Example of the ETH router connection: Figure 19: Example of router connection LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 24: Port1 Cable Connection

    RS422 WIFI MBUS WMBUS Description and examples of expansion ports connection can be found in user’s guide for corresponding expansion port. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 25: Port2 Cable Connection

    USB data signal – positive pole Input/Output Negative pole of DC supply voltage Table 9: Connection of USB connector Figure 22: USB connector LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 26: Connection Plc To The Router

    Data flow direction BIN0 Binary input Input Signálová zem OUT0 Binary output Output Table 10: Connection of I/O port Figure 25: I/O connector LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 27: Connection Of I/O Cable

    Circuit example of a binary input or output equipment with router: Figure 27: Connection of input and output to the router LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 28: Router Reset

    Figure 28: Router reset We recommend to backup your router configuration (see Configuration manual), because after reset router set configuration to the initial state. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 29: First Use

    The router can not operate without connected antenna, SIM card and power supply. If the antenna is not connected, router can be demaged. Figure 29: Router connection LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 30: Start

    192.168.1.1. Configuration may be performed only by the user "root" with initial password "root". A detailed description of the router settings via the Telnet interface can be found in the con- figuration manual. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 31: Technical Parameters

    PS bit rate 384 kbps (DL) / 384 kbps (UL) CS bit rate 64 kbps (DL) / 64 kbps (UL) W-CDMA FDD standard Continued on next page LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 32: Technical Parameters Of Cdma Module

    128 Mb FLASH 1 Mb MRAM Interface Serial interface RS232 Ethernet interface 10/100 Mbit/s USB 2.0 interface Table 15: Technical parameters of processor LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 33: Technical Parameters I/O Port

    7.6 Technical parameters of expansion port Technical parameters of the expansion ports are specified in separate manuals for expan- sion ports. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 34: Recommended Literature

    User’s manual – Expansion port SD, Conel: [12] Application guide – Expansion port mounting, [13] Conel: Application guide – Programmer guide. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 35: Possible Problems

    10 MB/s in property network cards, connect router over switch, start computer only after finalizing the start of the router. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 36: Faq

    IP address and by the help of the router address verify and address in ping. Firewall is possible to verify, for example by remote access on web interface. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 37 SMS message the router will be in this mode up to next restart. This behaviour is the same for next all control SMS messages. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 38: Customers Support

    Declaration of conformity was issued and it is possible to find it on the enclosed CD or at producer. LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...