PLANNING THE INSTALLATION

8
US
CA
IMPORTANT INSTALLATION INFORMATION
The range is tested in accordance with ANSI Z21.1 Standard for Household Cooking Gas Appliances.
The range must be installed in conjunction with a suitable overhead vent hood. (See section 'Ventilation
Requirements'). Due to the professional high heat capacity of this unit, particular attention should be paid to
the hood and duct work installation to ensure it meets local building codes. To eliminate risk of burns or fire by
reaching over heated surface units, cabinet storage located above the surface units should be avoided.
All range models with less than a 12" clearance between combustible material and the back edge of the
range (above the cooking surface) require the installation of one of the two offered Backguards – see section
'Backguard installation'.
All ranges have a standard 3-1/2" integral island trim.
RGU and RGUC ranges are supplied with a matching BGRU2-15xx standard backguard.
For RDU ranges, the backguard has to be purchased separately.
Wall Mount Full
Backguard
1-5/16"
Range Mount
Standard
Backguard
13/16"
Check local building codes for the proper method of range installation. Local codes vary. Installation, electrical
connections, and grounding must comply with all applicable codes. In the absence of local codes, the range
should be installed in accordance with the latest edition of National Fuel Gas Code ANSI Z223.1 and National
Electrical Code ANSI / NFPA 70.
Be sure that the unit being installed is set up for the kind of gas being used. The gas range is shipped from the
factory set and adjusted for Natural Gas or LP (propane), depending on the specific model ordered. Verify that
the range is compatible with the gas at the installation site before proceeding further. Return range to
dealer if the unit is not set for site gas supply.
26-1/2"
11-13/32"
Fig.1 Backguards