Hearthstone Quality Home Heating Products, Inc.
Note: The Standard Horizontal Vent Kit does
not require a restrictor.
The vent/air intake termination clearances above
the high side of an angled roof as follows:
Roof Pitch
Flat to 6/12
7/12 to 9/12
10/12 to 12/12
13/12 to 16/12
17/12 to 21/12
Figure 6
A
V
S
PPROVED
ENTING
C
OMPONENTS
Component Description
0
90
Elbow
0
45
Elbow
6" Straight
9" Straight
12" Straight
24" Straight
36" Straight
48" Straight
11"-14
Adjustable Pipe Length
5/8"
Horizontal Vent Cap
Vertical Vent Cap
Snorkel 36"
Vinyl Siding Standoff 4 x 6
Round Ceiling Support Wall
Thimble Covers
Wall thimble
If the vent air intake system, for any reason,
is disassembled, it must be reinstalled per the
instructions provided for in the initial
installation or in this manual.
V
C
ENT
ONFIGURATION
I. S
H
TANDARD
ORIZONTAL
Kit #93-65000)
Minimum horizontal run is 9"
N
OTE
Install the 45º elbow over the outer collar. Place
the elbow so that the twist lock end is pointing
up. Install the 2' pipe section into the elbow by
fully inserting it, and turning approximately ¼
Feet
Meters
1
0.3
2
0.6
4
1.2
6
1.8
8
2.4
YSTEM
5/8"
O
PTIONS
I
NSTALLATION
:
turn clockwise until the two sections are fully
locked. Install the 90º elbow in similar fashion.
N
: B
OTE
E SURE THERE IS NO
P
LUMBING IN THE CHOSEN WALL LOCATION
Move the stove and pipe assembly back until the
90º elbow is flush to the wall. The 2'vertical
pipe should be parallel to the wall. Draw a
circle around the pipe. Use the center of this
circle as the center point of the 10" x 10" square
wall pass through. Cut and frame the wall for
the vent pipe. Install the horizontal vent
termination on the outside of the wall. Make
sure both of the retaining straps extend through
the interior wall.
termination to the outside of the house, run a
bead of non-hardening mastic around the outside
edges, between the vent termination and the
wall. The arrow on the end cap should point up.
Secure the cap to the wall with the appropriate
screws.
Put the adjustable (11"-14") pipe into the
horizontal vent cap, (the vent pipe must extend
into the horizontal vent cap a minimum of 1 ¼").
Move the stove and vent pipe into position,
insert the adjustable (11"-14") pipe into the 90Ε
elbow, twist lock it. Secure the straps from the
horizontal vent termination to the interior pipe
with two sheet metal screws, keeping screws as
close to the wall thimble as possible. Bend or
cut the excess strapping so the thimble cover
will fit properly. Screw the thimble cover to the
wall.
The adjustment range of the wall
thickness for this configuration is
3"min- 9"max.