WARNING: IF THE INFORMATION IN THESE
INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A
FIRE, OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR
LOSS OF LIFE.
Do not store, or use gasoline, or other
flammable vapors and liquids near this, or
any other gas appliance!
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch electrical switches; do not use the phone
in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow your gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
A qualified installer, service agency, or gas supplier
must
perform
installation
Commonwealth of Massachusetts, all installation of
gas lines and gas fitting shall only be done by a
licensed gas fitter or licensed plumber.
and
service.
In
the
Santa Fe
DIRECT VENT HEATER
Owner's Manual
Operation & Installation Guide
READ THIS OWNER'S MANUAL
Operate and maintain this gas heater
according to this instruction manual.
Read this manual in its entirety.
AVERTISSEMENT:
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉERIEL, TOUTE BLESSURE OU LA MORT.
Ne pas entresposer ni utiliser d'essence ni
d'autre vaperurs ou liquides inflammables
dans le voisinage de cet apprareil ou de
tout autre appareil!
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous trouvez.
Appelez immédiatement votre fournisseur de gaz
depuis
un
voisin.
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifié
installer,
agence
fournisseur de gaz.
(Model 8761)
GAS-FIRED
ASSUREZ-VOUS
DE
Suivez
les
instructions
de
service
ou
Santa Fe Model: 8761
Manual: 6400-40451
Revised: 10/21/09
BIEN
du
le

Advertisement

Table of Contents
loading

Summary of Contents for HearthStone 8761

  • Page 1 L’installation et service doit être exécuté par un licensed gas fitter or licensed plumber. qualifié installer, agence service fournisseur de gaz. Santa Fe Model: 8761 Manual: 6400-40451 Revised: 10/21/09...
  • Page 2 Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Intentionally Blank Page 1 of 31...
  • Page 3: Information Sheet

    Use this page to record all relevant information concerning the purchase, installation, and maintenance of your Santa Fe Model 8761 Direct -Vent heater. This information will facilitate servicing, purchase of replacement parts, and warranty claims (if necessary). Keep your original receipt in a safe place as proof of purchase.
  • Page 4: Table Of Contents

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Table of Contents .......................... 4 NTRODUCTION ’ ......................5 WNER NFORMATION ..............................5 AILY PERATION ’ ......................6 NSTALLER NFORMATION ................................. 6 ODES ..........................6 NPACKING AND NSPECTION ........................
  • Page 5: Ntroduction

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater NTRODUCTION Congratulations on your purchase of Hearthstone’s valve control knob clockwise to “OFF”. Ensure the Santa Fe Gas-Fired Direct Vent heater. The unit is cool before servicing and cleaning.
  • Page 6: Wner Nformation

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater ’ WNER NFORMATION The installation must conform with local codes or, in a qualified service technician or gas the absences of local codes, the current National supplier.
  • Page 7: Installer ' S Information

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater ’ NSTALLER NFORMATION ODES NPACKING AND NSPECTION Adhere to ALL local codes or, in their absence, the Unpack and Inspect for Damage latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 (NFPA 54) or CAN/CGA B149...
  • Page 8: Specifications

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater * Tee joint *Gloves * Pipe wrench UPPLY * Phillips head screwdriver * Other parts as required by local code The Santa Fe Direct-vent does not require additional *Safety Glasses installer provided ventilation.
  • Page 9: Learances To Ombustibles

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Specification Input rating (Btu/hr) 0-2000 ft 35,000 35,000 Input rating (Btu/hr) 2000-4500 ft 35,000 33,300 Orifice size DMS 0-2000 ft Orifice size DMS 2000-4500 ft Man. press.-LO setting (in.w.c./kPa) 1.2/0.3...
  • Page 10: Venting Information

    (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used, available through your local Hearthstone dealer.
  • Page 11: Approved Possible Vent Termination Locations

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater PPROVED OSSIBLE ERMINATION OCATIONS Figure 6 - Acceptable Direct Vent Terminal Vent Cap Locations A = Clearance above grade, veranda, porch, deck, H = *Not to be installed within 15 feet (4.5m) above or balcony: 12 inches (30cm) minimum.
  • Page 12: Approved Venting System Components

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater ONFIGURATION PTIONS I. Standard Horizontal Vent Kit 93-65000 Horizontal Minimum horizontal run is 9”. Overhang Note: Install the 45º elbow over the outer collar. Place the elbow so that the twist lock end is pointing up.
  • Page 13 Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater II. Fireplace Venting Installations 1. 40' maximum system height (without offsets) 2. 14' maximum offset (refer to Figures 8-9) 3. Maximum rise to run = 1 to 5 (refer to Figures8- 4.
  • Page 14 Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Figure 10 – Vertical Venting Termination using Co-linear, Co-axial, or Class “A” Adaptors Page 13 of 31...
  • Page 15 Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater vinyl siding Stand off when installing against IV. Horizontal Termination Venting vinyl siding. Configurations 5. Horizontal sections require a 1/4" rise every 12" 1. A minimum of 24" rise is required (with or w/o of horizontal run.
  • Page 16: Vent Restrictor

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater ESTRICTOR To adjust your restrictor for maximum flame appearance, loosen the Phillips head screw and spin the locator, found on the rear left side of the stove. (Refer to figure 11) Figure 12 –...
  • Page 17: Gas Connections

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater ONNECTIONS Figure 13 The gas supply connection to the Santa Fe’s gas control valve is located under the unit on the left side and uses a 3/8" NPT fitting.
  • Page 18: Replacing The Glass

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater WHEN INSTALLING THE LOGS BE SURE NOT TO EPLACING THE LASS COVER ANY SLOTTED PORTS ON THE BURNER SURFACE To replace the front glass, shut the pilot light off.
  • Page 19: Removal Of Log Set

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Gently slide the shortest of the “half” logs (3) Spread evenly across the front portion of the onto pin B as shown below. Pan Burner, one layer high, the Charcoal Embers.
  • Page 20: Peration

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater PERATION IS DESIGNED TO OPERATE BY HAND. DO NOT IGHTING THE NIT THE IRST USE ANY TOOLS DURING THIS OPERATION. MOKE AND UMES ARNING When lit for the first time, the Santa Fe will emit some smoke and odors.
  • Page 21: Gas Conversions

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater converted for use with LP, and visa versa. The instructions provided with the included conversion kit must be followed. Only a Qualified Gas Technician should perform the conversion.
  • Page 22: Routine Maintenance And Care

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater OUTINE AINTENANCE AND fasten the door shut and briefly light the unit he Santa Fe requires minimal routine maintenance according to lighting instructions described on Page and care. The unit should always be cool and off 4.
  • Page 23: Wiring Instructions

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Figure 17 (Attention: Au moment de l’entretien des Wiring Instructions commandes, étiquetez tous les fils avant le Caution: Label all wires prior to disconnection débranchement. Des erreurs de câblage when servicing controls.
  • Page 24: Parts List

    Remote Control Thermostat WARNING! DO NOT SUBSTITUTE MATERIALS. For replacement parts, or for information about parts or service, contact your authorized Hearthstone retailer. For the name of the authorized retailer nearest to you, visit our website at www.Hearthstonestoves.com, or e-...
  • Page 25: Rating Label

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater ATING ABEL...
  • Page 26: Roubleshooting Uide

    Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater ROUBLESHOOTING UIDE Symptom Possible Cause Corrective Action 1. Pilot will not A. Using the piezo sparker, try to light the pilot. If it will not A. Insufficient gas pressure, light.
  • Page 27 Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Symptom Possible Cause Corrective Action 3. Pilot burning, no A. Thermostat switch or A. Check thermostat/wiring for proper connections. Place gas to main burner, wires defective. jumper wire across terminals at thermostat. If burner comes valve knob in the on, replace defective thermostat.
  • Page 28 Hearthstone Quality Home Heating Products, Inc. SANTA FE 8761 Gas-Fired Direct Vent Heater Symptom Possible Cause Corrective Action 8. Floating flames, A. Potentially dangerous A. Check the appliance input rate and reduce if necessary. lazy ill-defined, incomplete combustion due The air intake/exhaust flow system may be too restrictive or...
  • Page 29: Limited Warranties

    Accessories and electrical components such as blowers, switches and thermo discs, excluding venting components, hearth components, electrical components and other components or accessories used in conjunction with the installation of the Stove not manufactured, or supplied by Hearthstone – against breakage or malfunction.
  • Page 30 9. A defect in any part of the Stove if the Original Purchaser fails to comply with Hearthstone’s or a Dealer’s request to ship the part or the Stove to Hearthstone or a Dealer, as the case may be.
  • Page 31 Stove to and from Hearthstone or an authorized Dealer, as the case may be. Notwithstanding any other provision of this document, in no event will Hearthstone pay for any Dealer fees or other fees for pick up or delivery of the Gas Stove returned for repair; the Original Purchaser shall be responsible for any such fees.