HearthStone Santa Fe 8761 Owner's Manual page 15

Gas-fired direct vent heater
Hide thumbs Also See for Santa Fe 8761:
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc.
Figure 9
IV. Horizontal Termination Venting
Configurations
-A minimum of 24" rise is required (with or w/o
offsets)
-40' maximum system height (without offsets)
-Maximum rise to run = 1 to 5 (refer to Figures
8 & 9)
-The termination must fall within the area
outlined by the shaded area shown in Figure 7.
The Authority Having Jurisdiction must be consulted before
proceeding with these installation methods.
Use a vinyl siding Stand off when installing
against vinyl siding.
-Horizontal sections require a 1/4" rise every 12"
of horizontal run.
0
-For each 90
elbow after the second, remove 5'
from horizontal run.
-Use with snorkel termination 45" maximum
horizontal run.
-Minimum horizontal run is 9".
14
SANTA FE Model 8761