INSTALLATION
INSTALLING / REPLACING THE LAMP
DANGER TO LIFE: only install the lamp when the device switched off. Unplug from
mains before
For the installation, you need one HMI 575W GS lamp respecting the manufacturer's
specifications
CAUTION: the lamp has to be replaced when it is damaged or deformed due to the heat.
The lamp life given by the manufacturer must never be exceeded.
During the operation, the lamp reaches temperatures up to 600 °C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx.
15 minutes).
During the installation do not touch the glass-bulbs bare-handed. Please follow the lamp
manufacturer's notes.
Do not install lamps with a higher wattage. Lamps with a higher wattage generate
temperatures that the device was not designed for. Damages caused by non observance
are not subject to warranty.
REPLACING THE LAMP
1.
Unscrew the fixation screws of the lamp cover and remove it
2.
If replacing the lamp, remove the hold lamp from the lamp holder
3.
Insert the lamp into the lamp holder
4.
Replace the lamp cover and tighten the fixation screws
5.
Ad just the lamp as described under lamp adjustment
Do not operate this device with opened cover.