4.3

Technical specifications

System voltage
Voltage range
Standby power consumption
Active power consumption
Storage temperature
Operational temperature
Maximum bus cable length
Maximum number of nodes
Maximum length of bus cables (for boats)
Maximum load with 15 m of bus cable
Maximum number of bus cables
Weight of a 130 A system with 20 nodes
Complies to
International standards
CE approval
EMC approvals
: 12 V
: 10-16 V
: <10 mA
: Approximately 100 mA
: -20 ºC to +70 ºC (-4 °F to 158 °F)
: -4 ºC to +50 ºC (24 °F to 122 °F)
: 100 m / 328 ft
: 255
: 15 m / 50 ft
: 50 A
: Indefinite
: 20 kg / 44 lbs
: 94/25/EC and 89/336/EEC
: ISO 10133
: Yes
: EN 61000-6-2 (2001) and EN 61000-6-3
(2001)