Warning Lights; Indications Of The Appliances - Victron energy VE.Net DC Installation & Operation Manual

Bus-based power distribution system
Table of Contents

Advertisement

Installation & operation manual

Warning lights

The two warning light on the push-button
panel warn you for the following failures:
Wrong polarity
Overload of the system / low voltage

Indications of the appliances

Each appliance is automatically tested
during its operation. In that case, the
light in the switch button is green.
Other indications in the push-buttons are
explained in the table.
In case of a failure, turn off the appliance
with the push-button. The buzzer,
indication led and automatic fuse are
reset. Repair the appliance. Switch on
the appliance to test.
Light
Buzzer
Polarity
Continuous
Overload
Interrupted
Light
Buzzer
Green
No
Blinking
Yes
green
Blinking
Yes
green / red
Blinking red
Yes
Meaning
Battery connected wrong, the
+ and – connectors have
been mismatched
The system is overloaded or
the battery voltage is too low
(battery is discharged).
Meaning
Appliance is turned on and
functions normally.
No appliance. Light defective
or wire between node and
appliance defective.
Circuit is nearly overloaded or
node is nearly overheated.
Circuit is overloaded or
overheated and turned off
automatically
B L U E
P O W E R
Action
Turn off all fuses in the fuse
box.
Check the polarity of battery
and change it correctly.
Devices may be overheated
and damaged if the polarity
was wrong for over a minute.
Turn off appliances that are
not absolutely necessary. If
the situation continues, the
system switches off
appliances automatically in
order of priority.
Action
Check lights or wires.
Press the – button to reset
the buzzer.
Turn off the node.
Push the switch button to
reset. Check the wires from
the node to the appliance for
short circuits.
27

Advertisement

Table of Contents
loading

Table of Contents