4.2

Replace the node

1. Switch off all fuses.
2. Unplug the connectors on the node.
Make sure which connector is
connected to + and –.
3. Push a screwdriver into the node for
approximately 5 mm.
4. Turn the screwdriver; you may need
to apply some force because of
possible corrosion.
5. Push in the new node.
Note: Make sure to replace the node
with a new one of the same type.
6. Configure the node. Refer to
Configure the system.
32

If no new nodes are available:

Warning!
Use this procedure only in
case of an emergency and
when no spare parts are
available.
Warning!
Make sure the + and – cables
cannot make contact with
each other. Possible risk of
short circuit!
Installation & operation manual
Red/Violet
For appliances connected via a power
node:
1. Disconnect the node. Follow steps 1
to 4 of the procedure on the left.
2. Place a wire between the black cable
of the bus and the black cable of the
appliance.
3. Take a fuse with the same rating as
the corresponding node.
4. Place the fuse with a wire between
the red cable of the bus and the red
cable of the appliance.