Maintenance; Troubleshooting - Victron energy VE.Net DC Installation & Operation Manual

Bus-based power distribution system
Table of Contents

Advertisement

Installation & operation manual

4 Maintenance

4.1

Troubleshooting

Problem
Polarity light is illuminated, a continuous
beep is heard.
No action when the
/
ON
OFF
pushed.
After a button is pushed, no warnings and
no power at the appliance.
Overload light is illuminated, a interrupted
beep is heard.
Switch blinks red, a beep is heard.
Switch blinks green, a beep is heard.
Bilge-pump or instruments connected via
a direct power node cannot be turned off.
Possible cause
Battery is connected wrong.
button is
The 10 A fuse in the main fuse box is
released.
Push button panel is connected
wrong.
The 50 A fuse in the main fuse box is
released.
Bus cable and node are connected
wrong.
The voltage is low.
The circuit is overloaded.
Short circuit between node and
appliance.
Wire between node and appliance is
defective.
Light is defective.
The bypass fuse of the direct power
node is switched on.
DPN is defective.
Possible solution
Turn off the main power immediately.
Check the polarity of the battery
connection.
Check the voilet bus wire.
Reset the fuse
Check the connections of the switch
panel. Reconnect if necessary.
Check the red plus wire.
Reset the fuse.
Check the connections between bus
cable an the node. Reconnect if
necessary.
Turn off appliances. If not, the system
turns off appliances automatically by
order of priority.
Check the wires between the
appliance and node.
In case of a built-in safety device in
the appliance: turn off the warning.
Refer to Feedback defective
lamp/cable.
Replace the lamp of the light.
Turn off the bypass fuse of the DPN.
Turn off the power of the DPN.