OPTOKON EDFA User Manual page 53

Optical amplifier
Table of Contents

Advertisement

AS{cr}
Reports any problems with the EDFA module:
Indicator
STAGE 1 IN LOS
STAGE 2 IN LOS
STAGE 1 OUT LOS
STAGE 2 OUT LOS
TINT
PTMP
PUMP BIAS
ADI
OPMI
GA{sp}[1,2]{cr} Reports Amplifier Gain in dB for each stage (ASEcorrected)
EDFA Module Status Request
Parameters
Loss of input signal alarm
stage 1 and stage 2
Loss of output signal alarm
stage 1 and stage 2
Internal Temperature Alarm
Pump temperature alarm
Pump bias current alarm
Disable Alarm
Eye-safe Power Control Input
(mute)
Reply is:
STATUS:{sp}ADI{sp}OPMI{sp}PTMP{sp}PI{cr}
Example usage:
GA{sp}1{cr}
Reply is:
GAIN STAGE 1:{sp}18{sp}dB{cr}
The amplifier gain stage 1 is 18 dB.
In AGC OADM mode, GA 1 value should the same as AGC 1 set value, and
GA 2 value should the same as AGC 2 set value.
EDFA optical amplifier – user manual
The loss of input power will send an
alarm on the RS232 port when
sending alarm status command and on
the electric connector (TTL signal).
The value of the input power alarm
threshold is settable and may be
disabled.
The loss of output power will send an
alarm on the RS232 port (when
sending alarm status command), and
on the electric connector (TTL signal).
This feature may announce a possible
EDFA problem. The value of the loss
of output power alarm threshold is
settable and may be disabled.
TINT indicates that the EDFAs internal
case temperature is out of limits.
This feature sends an alarm if one or
several laser diode exceed the set
value by 2° C.
This feature sends an alarm if one or
several laser diode currents exceed 95
% of end of life current.
ADI indicates that the disable electrical
input pin is active. In DI state, the laser
diode power supply is turned off by a
transistor. The TEC power supply stay
turned on.
When active, the output power for
each stage is set to mute power (ALS
values)