OPTOKON EDFA User Manual page 30

Optical amplifier
Table of Contents

Advertisement

Setting ACC mode / setting current of Pump diode [mA]
ACC
Setting AGC mode / setting constant Gain [dB]
AGC
Enabled or Disabled Laser shutdown function
ALSFNC
Setting output power value when Loss input alarm is active [dBm]
ALSVAL
Setting APC mode / setting constant Output power [dBm]
APC
Loss of input alarm – 1 Active / 0 Not active
INLOS
Loss of output alarm – 1 Active / 0 Not active
OUTLOS
Actual gain report [dB]
GAIN
Temperature control current [mA]
TEC_1_CURRENT
First pump diode current [mA]
LD_1_CURRENT
Setting threshold value Loss of input alarm [dBm]
LI
Setting threshold value Loss of output alarm [dBm]
LO
Output power from pump diode [mW]
PLD_1_POWER
Pump diode Temperatures [°C]
PLD_1_TEMP
Input optical power [dBm]
POWER_IN
Output optical power [dBm]
POWER_OUT
Set maximal output power [dBm] – protect EDFA unit
POWER_MAX
Set maximal gain [dB] – protect EDFA unit
GAIN_MAX
Set maximal pump diode current [mA] – protect EDFA unit
CURRENT_MAX
Enable or Disable Auto power reduce function
APRFNC
EDFA optical amplifier – user manual
Picture 11 - Expert mode setting
Table 8 - Expert mode