9.2 Login to the CLA

After the PC is switched on you can login to your CLA system. Type login and
password
Factory setting of login:
NOTE: for change of password use command "passwd"
After login to the CLA, system displays the MOTD message "Message Of The
Day"
Message
Serial Number:
Device:
CLDDistro ver.:
Location:
Line:
Admin:
To change the default MOTD the following procedure shall be used:
 Edit file
 Run file
 Display new MOTD

9.3 IP address setting

For change or setting of IP address use file /etc/network/interfaces.
In this file you can set IP addresses of all network cards
Default Ethernet setting:
Example of file for functionally interface eth1 with static IP address:
allow-hotplug eth0
auto eht0
iface eth0 inet static
address 192.168.123.123
netmask 255.255.255.0
gateway 192.168.123.255
NOTE: the attribute "#" means commentary
Login:
Password:
Description
Serial number of device
Type of device
Software distribution version
Location of the CLA
Trace from to
Administrator name
Administrator email
Administrator phone
/etc/motd.sheet
/etc/init.d/cld-motd
cat /etc/motd
NET_IP 192.168.0.10
NET_MASK 255.255.255.0
NET_GATEWAY 192.168.0.1
ifconfig eth0
EDFA optical amplifier – user manual
root
optokon
Parameter
SERIAL
DEVICE_TYPE
VERSION
LOCATION
LINE
ADMIN
ADMIN_EMAIL
ADMIN_PHONE
19