11.2 Detailed Installation

The recommended components for an installation protected for nearby strikes are:
Grounding Kits — Andrew Type 223158-2
Screened CAT 5e Cable also known as Shielded CAT 5e or CAT 5e STP (Shielded
Twisted Pair)
NB: Only use Outdoor rated, gel filled CAT5e if it contains a shield.
Surge Arrestor: Transtector Type ALPU-ORT - 4 per link (www.transtector.com)
Grounding Stake
RJ45 screened connectors
8 AWG Grounding Cable – Minimum size, preferably 6 or 4
Note: There may be a local regulatory requirement to cross bond the CAT 5e cable at regular
intervals to the mast. This may be as frequent as every 10 meters (33 feet)
(http://www.andrew.com